Machine wiring
Wire numbers by machine
Select a machine or search across the complete wire register.
Wire register
821 results| Machine | Wire number | Name / definition | Optional extra | Notes | From | To | |
|---|---|---|---|---|---|---|---|
| ATCUACC112-40 200 - 240VAC 3 PH | 0 | AC neutral / control neutral | YES — SHAREDPsychometric Unit Option | Shared standard neutral. It also returns the GP35 pump circuit associated with the psychometric option. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 1 | 3-phase distribution conductor | NO | The '1' shown at the Psychometric Unit connector on page 3 is a connector pin, not this wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 10 | Stage 1 compressor phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 100 | 3-phase power conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 101 | 3-phase power conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 102 | 3-phase power conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 11 | Stage 2 compressor phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 110 | Transformer secondary phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 111 | Transformer secondary phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 112 | Transformer secondary phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 114 | Heater supply phase | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 115 | Heater supply phase | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 116 | Heater supply phase | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 12 | Stage 2 compressor phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 122 | Condenser fan branch feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 123 | Condenser fan switched feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 124 | De-superheater fan branch feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 125 | De-superheater fan switched feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 126 | Crankcase-heater branch feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 127 | Crankcase heater stage 1 switched feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 128 | Crankcase heater stage 2 switched feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 13 | Stage 2 compressor phase conductor | NO | The '13' shown beside B1 on page 3 is a connector pin, not this power wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 14 | Heater phase feed after contactor C4 | NO | The '14' shown beside B1 on page 3 is a connector pin, not this power wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 15 | Heater phase feed after contactor C4 | NO | The '15' shown beside B1 on page 3 is a connector pin, not this power wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 150 | Stage 1 COOL solenoid feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 151 | Stage 1 BYPASS solenoid feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 152 | Stage 2 COOL solenoid feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 153 | Stage 2 BYPASS solenoid feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 154 | DEHUMID solenoid feed | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 16 | Heater phase feed after contactor C4 | NO | The '16' shown beside B2 on page 3 is a connector pin, not this power wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 164 | Plant healthy output | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 17 | Heater switched output | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 18 | Heater switched output | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 19 | Heater switched output | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 2 | 3-phase distribution conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 210 | HEAT command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 24 | +24 V DC control supply | NO | Page 1 standard: pink, 0.5 mm². The explicitly marked Psychometric Unit option does not show a direct 24 V wire connection. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 248 | GP35 pump switched AC feed | YESPsychometric Unit Option | Revision H states the psychometric fill/drain valves were replaced by a pump; this is the GP35 pump circuit. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 265 | RUN command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 286 | HUMIDIFY command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 289 | Psychometric option control signal | YESPsychometric Unit Option | Explicitly inside the area labelled 'PSYCHOMETRIC UNIT OPTION' and routed to SSR9. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 3 | 3-phase distribution conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 4 | AC live / control supply feed | YES — SHAREDPsychometric Unit Option | Shared standard AC feed. SSR9 uses it to switch the optional GP35 psychometric pump. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 43 | Air circulation fan contactor command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 44 | Stage 1 compressor contactor command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 45 | Stage 2 compressor contactor command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 46 | Heater contactor command before over-temperature interlock | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 5 | Air circulation fan phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 50 | Stage 1 cooling-solenoid relay command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 51 | Stage 1 bypass-solenoid relay command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 52 | Stage 2 cooling-solenoid relay command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 53 | Stage 2 bypass-solenoid relay command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 54 | Dehumidification solenoid relay command | NO | Function follows the Q8-Q12 relay/solenoid sequence shown on page 3. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 55 | PLC output Q13 | NO | Function not defined by the source drawing. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 560 | DEHUMID command / control signal | NO | Dehumidifier is shown as part of the ATCU circuit and is not explicitly labelled optional. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 57 | Heater contactor command after OT2 | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 6 | Air circulation fan phase conductor | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 68 | COOL command | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 7 | Air circulation fan phase conductor | NO | The '7' shown at the Psychometric Unit connector on page 3 is a connector pin, not this wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 74 | Air temperature limit input | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 75 | PLC input I4 | NO | Function not defined by the source drawing. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 76 | PLC input I5 | NO | Function not defined by the source drawing. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 77 | PLC input I6 | NO | Function not defined by the source drawing. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 78 | PLC input I7 | NO | Function not defined by the source drawing. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 79 | Heater contactor feedback | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 8 | Stage 1 compressor phase conductor | 0 V DC common | YES — SHAREDPsychometric Unit Option | Context-specific use on the power circuit; the drawing also uses wire 8 as the 0 V DC identifier. Page 1 standard: violet, 0.5 mm². Shared 0 V rail; SSR9 for the psychometric option returns on wire 8. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 80 | Recirculation fan overload feedback | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 81 | Stage 1 compressor overload feedback | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 82 | Stage 2 compressor overload feedback | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 83 | Stage 1 pressure-switch feedback | NO | The drawing shows two Stage 1 HP/LP1 feedback conductors, 83 and 84. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 84 | Stage 1 pressure-switch feedback | NO | The drawing shows two Stage 1 HP/LP1 feedback conductors, 83 and 84. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 85 | Stage 2 pressure-switch feedback | NO | The drawing shows two Stage 2 HP/LP1 feedback conductors, 85 and 86. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 86 | Stage 2 pressure-switch feedback | NO | The drawing shows two Stage 2 HP/LP1 feedback conductors, 85 and 86. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 87 | Stage 2 HP1 feedback | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 9 | Stage 1 compressor phase conductor | NO | The '9' shown at the Psychometric Unit connector on page 3 is a connector pin, not this wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 92 | Heater SSR control | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | 93 | Y3 solenoid command | NO | Drawing does not give a separate functional label for Y3. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | E | Supply earth / protective earth | NO | Page 1 wire-identification standard. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | L1 | Mains supply phase L1 | NO | Page 1 standard: black, 4 mm². | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | L11 | Phase conductor after main RCD | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | L2 | Mains supply phase L2 | NO | Page 1 standard: black, 4 mm². | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | L21 | Phase conductor after main RCD | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | L3 | Mains supply phase L3 | NO | Page 1 standard: black, 4 mm². | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | L31 | Phase conductor after main RCD | NO | — | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | R | Incoming supply phase identifier | NO | Supply label rather than a numbered control wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | S | Incoming supply phase identifier | NO | Supply label rather than a numbered control wire. | Edit | ||
| ATCUACC112-40 200 - 240VAC 3 PH | T | Incoming supply phase identifier | NO | Supply label rather than a numbered control wire. | Edit | ||
| CFXCorroflex | 0L | ACC29 ATCU local neutral | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 1 | Incoming mains cable core for L1 | NO | — | Edit | ||
| CFXCorroflex | 10 | Over-temperature thermostat O/T1 | O/T1 input | NO | — | Edit | ||
| CFXCorroflex | 100 | Z1 output / chamber power distribution | NO | — | Edit | ||
| CFXCorroflex | 1000 | Heater/blower mains distribution conductor | NO | — | Edit | ||
| CFXCorroflex | 1001 | Heater/blower mains distribution conductor | NO | — | Edit | ||
| CFXCorroflex | 1002 | Heater/blower mains distribution conductor | NO | — | Edit | ||
| CFXCorroflex | 1004 | Heater/blower auxiliary supply; also air-drying blower supply | Air drying blower supply | NO | — | Edit | ||
| CFXCorroflex | 1005 | Air saturator heater supply | NO | — | Edit | ||
| CFXCorroflex | 101 | Z1 output / chamber power distribution | Shared power/supply conductor used by ACC30 / ACC102 circuits | YES — SHAREDACC30 / ACC102 | — | Edit | ||
| CFXCorroflex | 102 | Z1 output / chamber power distribution | NO | — | Edit | ||
| CFXCorroflex | 105 | ATCU air circulation fan phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 106 | ATCU air circulation fan phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 107 | ATCU air circulation fan phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 108 | ATCU compressor stage 1 phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 109 | ATCU compressor stage 1 phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 11 | Over-temperature thermostat O/T2 | O/T2 input | NO | — | Edit | ||
| CFXCorroflex | 110 | ATCU compressor stage 1 phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 111 | ATCU compressor stage 2 phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 112 | ATCU compressor stage 2 phase conductor | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 113 | Blower over-temperature thermostat O/T6 circuit | ATCU compressor stage 2 phase conductor | YES — SHAREDACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 1133 | User Programmable Digital Output 2 | YESUser programmable output 2, User Programmable Digital Output 2 | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 114 | ATCU heater contactor input phase | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 115 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | ATCU heater contactor input phase | YES — SHAREDACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 116 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | ATCU heater contactor input phase | YES — SHAREDACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 117 | Sulphur Dioxide Supply Valve | Sulphur dioxide supply valve | YESACC46 Sulphur dioxide dosing | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 1180 | User Programmable Digital Output 2 relay/contact conductor | YESUser Programmable Digital Output 2 | — | Edit | ||
| CFXCorroflex | 1181 | User Programmable Digital Output 2 relay/contact conductor | YESUser Programmable Digital Output 2 | — | Edit | ||
| CFXCorroflex | 1182 | User Programmable Digital Output 2 relay/contact conductor | YESUser Programmable Digital Output 2 | — | Edit | ||
| CFXCorroflex | 1183 | User Programmable Digital Output 2 relay/contact conductor | YESUser Programmable Digital Output 2 | — | Edit | ||
| CFXCorroflex | 1189 | Phase input to Z1 | NO | — | Edit | ||
| CFXCorroflex | 121 | Air Saturator 2 full | YESSecond air saturator option | Used when the second air saturator / door-seal control is fitted. | Edit | ||
| CFXCorroflex | 122 | ATCU condenser fan branch feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 123 | ACC20 waste-water trough full switch | ACC20 full switch | Common feed used by user programmable digital outputs | YES — SHAREDACC20 Waste water trough & pump, User programmable digital outputs | — | Edit | ||
| CFXCorroflex | 1233 | User Programmable Digital Output 4 | YESUser Programmable Digital Output 4, Remote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 124 | ATCU de-superheater fan branch feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 125 | ACC92 scrubber flow signal | Scrubber flow meter signal | YESACC92 Exhaust salt scrubber | — | Edit | ||
| CFXCorroflex | 126 | ATCU crankcase-heater branch feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 1265 | ACC29 Butterfly Valve | Refrigeration & humidity control butterfly valve | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 127 | ATCU crankcase heater stage 1 feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 128 | ATCU crankcase heater stage 2 feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 132 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 133 | User Programmable Digital Output 1 | YESUser programmable output 1, User Programmable Digital Output 1 | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 134 | Spot Cooler | Spot cooler relay command | YESACC90 Spot cooler | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 135 | Air Saturator 2 Water/Fog changeover solenoid | YESSecond air saturator option | — | Edit | ||
| CFXCorroflex | 136 | Multi Solution changeover solenoid | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 137 | Additional Side Heater Mats | Additional side heater mats relay command | YESAdditional side heater mats | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 139 | Additional side heater mat switched conductor | YESAdditional side heater mats | — | Edit | ||
| CFXCorroflex | 14 | Moist air valve | Moist air | NO | — | Edit | ||
| CFXCorroflex | 144 | Interior illumination switched mains feed after MCB7 | NO | — | Edit | ||
| CFXCorroflex | 146 | ACC102 salt solution consumption sensor signal | Salt solution consumption sensor signal | YESACC102, ACC102 Salt solution consumption sensor | — | Edit | ||
| CFXCorroflex | 147 | Salt tank low-water alarm | Salt tank low water alarm | YESACC59 salt tank alarm option | — | Edit | ||
| CFXCorroflex | 148 | Second blower ball valve position/contact conductor | YESACC39 / ACC47 Blower ball valve | — | Edit | ||
| CFXCorroflex | 150 | ATCU stage 1 COOL solenoid switched feed | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 151 | ATCU stage 1 BYPASS solenoid switched feed | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 152 | ATCU stage 2 COOL solenoid switched feed | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 153 | ATCU stage 2 BYPASS solenoid switched feed | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 154 | ATCU DEHUMID solenoid switched feed | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 1580 | User Programmable Digital Output 4 relay/contact conductor | YESUser Programmable Digital Output 4 | — | Edit | ||
| CFXCorroflex | 1581 | User Programmable Digital Output 4 relay/contact conductor | YESUser Programmable Digital Output 4 | — | Edit | ||
| CFXCorroflex | 1582 | User Programmable Digital Output 4 relay/contact conductor | YESUser Programmable Digital Output 4 | — | Edit | ||
| CFXCorroflex | 1583 | User Programmable Digital Output 4 relay/contact conductor | YESUser Programmable Digital Output 4 | — | Edit | ||
| CFXCorroflex | 164 | ATCU OK | ATCU plant healthy | YES — SHAREDACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 17 | ATCU heater SSR1 output | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 170 | Blower ball-valve position | Blower ball valve position feedback | YESACC39 / ACC47 Blower ball valve | — | Edit | ||
| CFXCorroflex | 173 | Low water | Water low input | NO | — | Edit | ||
| CFXCorroflex | 177 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 18 | Emergency stop feedback | Emergency stop input | ATCU heater SSR2 output | YES — SHAREDACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 180 | User Programmable Digital Output 1 relay/contact conductor | YESUser Programmable Digital Output 1 | — | Edit | ||
| CFXCorroflex | 181 | User Programmable Digital Output 1 relay/contact conductor | YESUser Programmable Digital Output 1 | — | Edit | ||
| CFXCorroflex | 182 | User Programmable Digital Output 1 relay/contact conductor | YESUser Programmable Digital Output 1 | — | Edit | ||
| CFXCorroflex | 183 | User Programmable Digital Output 1 relay/contact conductor | YESUser Programmable Digital Output 1 | — | Edit | ||
| CFXCorroflex | 185 | Psychometric drains | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 187 | Phase input to Z1 | NO | — | Edit | ||
| CFXCorroflex | 188 | Phase input to Z1 | NO | — | Edit | ||
| CFXCorroflex | 1889 | Phase feed from X1 to MCB30 / MCB3 | NO | — | Edit | ||
| CFXCorroflex | 189 | Phase feed after MCB30 to optional ATCU power pages | NO | — | Edit | ||
| CFXCorroflex | 1890 | ACC29 ATCU phase after MCB21 | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 19 | Canopy opened | Canopy opened input | ATCU heater SSR3 output | YES — SHAREDACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 191 | Spot cooler mains feed after MCB15 | YESACC90 Spot cooler | — | Edit | ||
| CFXCorroflex | 196 | Air Saturator 2 heater inhibit | YESSecond air saturator option | Used when the second air saturator / door-seal control is fitted. | Edit | ||
| CFXCorroflex | 198 | Heater over-temperature count / O/T10 chain | Heater over-temperature count input | NO | — | Edit | ||
| CFXCorroflex | 1981 | O/T11 thermostat intermediate conductor | NO | — | Edit | ||
| CFXCorroflex | 1L | ACC29 ATCU local phase 1 | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 2 | Incoming mains cable core for L2; also reused as AC neutral in internal circuits | Air drying blower neutral | Shared power/supply conductor used by ACC30 / ACC102 circuits | YES — SHAREDACC30 / ACC102 | — | Edit | ||
| CFXCorroflex | 20 | Auto fill valve | Auto fill | NO | — | Edit | ||
| CFXCorroflex | 21 | Air saturator full | Air saturator full input | NO | — | Edit | ||
| CFXCorroflex | 210 | Heat | ATCU HEAT input | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 213 | Remote PAUSE | YESRemote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 214 | Remote UNPAUSE | YESRemote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 215 | Remote START | YESRemote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 216 | Remote STOP | YESRemote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 217 | Two Button Canopy Option input | YESRemote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 22 | Air saturator low | Air saturator low input | NO | — | Edit | ||
| CFXCorroflex | 222 | Air Saturator 2 low | YESSecond air saturator option | Used when the second air saturator / door-seal control is fitted. | Edit | ||
| CFXCorroflex | 233 | User Programmable Digital Output 3 | YESUser Programmable Digital Output 3, Remote controls / Two-button canopy / user outputs | — | Edit | ||
| CFXCorroflex | 236 | Door/open control feed before E-stop interlock | NO | — | Edit | ||
| CFXCorroflex | 237 | Door/close control feed before E-stop interlock | NO | — | Edit | ||
| CFXCorroflex | 238 | Door seal control feed before E-stop interlock | NO | — | Edit | ||
| CFXCorroflex | 239 | Door unseal control feed before E-stop interlock | NO | — | Edit | ||
| CFXCorroflex | 24 | +24 V DC control supply | +24 V supply to optional output cards | Supply to PT100 / analogue cards including ACC34 option | Shared supply/return used by page 15 optional accessories | Shared supply/return to ACC42 / ACC46 / ACC29 accessories | Shared supply/return to ACC92 / ACC31 / ACC66 / ACC59 accessories | Shared power/supply conductor used by ACC30 / ACC102 circuits | Shared supply/return for page 19 optional accessories | Shared supply/return for ACC36 remote transmission and optional remote controls | YES — SHAREDOptional output cards, ACC34 optional PT100, ACC20 / ACC90 / additional pump options, ACC42 / ACC46 / ACC29, ACC92 / ACC31 / ACC66 / ACC59, ACC30 / ACC102, ACC39 / ACC47 / ACC05 / user outputs, ACC36 / Remote controls / Two-button canopy | Defined by the wire-identification table on page 1. ACC34 sensor leads are colour/terminal identified rather than assigned separate numeric wire IDs. | Edit | ||
| CFXCorroflex | 24L | ACC29 ATCU +24 V DC | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 25 | Open canopy | NO | — | Edit | ||
| CFXCorroflex | 250 | Air distribution bar | Air bar | NO | — | Edit | ||
| CFXCorroflex | 252 | Salt Spray Motor Run | Salt spray vertically-down motor run relay command | YESACC30 Salt spray vertically down | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 26 | Dry air valve | Dry air | NO | — | Edit | ||
| CFXCorroflex | 265 | Run | ATCU RUN input | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 27 | Close canopy | NO | — | Edit | ||
| CFXCorroflex | 28 | Canopy closed | Optional pneumatic sensor switch S23 connection into canopy-closed input | Canopy closed input | YES — SHAREDOptional pneumatic sensor switch S23 | The drawing labels S23 'PNEUMATIC SENSOR SWITCH OPTIONAL'. | Edit | ||
| CFXCorroflex | 286 | Humidify | ATCU HUMIDITY input | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 289 | P_Fill | Psychometric water fill / P_Fill | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 2L | ACC29 ATCU local phase 2 | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 3 | Incoming mains cable core for L3 | NO | — | Edit | ||
| CFXCorroflex | 31 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 311 | Air curtain | NO | — | Edit | ||
| CFXCorroflex | 317 | ATCU heater 1 feed after protection | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 318 | ATCU heater 2 feed after protection | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 319 | ATCU heater 3 feed after protection | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 32 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 323 | ATCU condenser fan switched feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 325 | ATCU de-superheater fan switched feed | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 33 | Blower Ball Valve(s) c/w Position Switch(es) | Blower ball valve drive | YESACC39 / ACC47 Blower ball valve | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 34 | Buzzer | NO | — | Edit | ||
| CFXCorroflex | 340 | Door seal command after emergency-stop interlock | Door seal | NO | — | Edit | ||
| CFXCorroflex | 341 | Door unseal command after emergency-stop interlock | Door unseal | NO | — | Edit | ||
| CFXCorroflex | 342 | Door sealed feedback | Door sealed | NO | Used when the second air saturator / door-seal control is fitted. | Edit | ||
| CFXCorroflex | 343 | Canopy unsealed | NO | Used when the second air saturator / door-seal control is fitted. | Edit | ||
| CFXCorroflex | 344 | ATCU compressor stage 1 contactor | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 345 | ATCU compressor stage 2 contactor | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 35-1 | Air saturator 1 heater circuit | NO | — | Edit | ||
| CFXCorroflex | 35-2 | Air saturator 2 heater circuit | NO | — | Edit | ||
| CFXCorroflex | 350 | ATCU stage 1 cool solenoid relay | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 352 | Salt spray vertically-down motor switched conductor | YESACC30 Salt spray vertically down | — | Edit | ||
| CFXCorroflex | 353 | Salt spray vertically-down motor relay output conductor | YESACC30 Salt spray vertically down | — | Edit | ||
| CFXCorroflex | 354 | ATCU dehumidification solenoid relay | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 36 | Air saturator heater relay command | Air saturator heater | NO | — | Edit | ||
| CFXCorroflex | 37 | Chamber heater relay command | Chamber heater | NO | — | Edit | ||
| CFXCorroflex | 370 | Inverter enable | NO | — | Edit | ||
| CFXCorroflex | 374 | ATCU air temperature limit (60C) | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 375 | ATCU PLC input I4 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 376 | ATCU PLC input I5 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 377 | ATCU PLC input I6 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 38 | Immersion heater relay command | Immersion heater | NO | — | Edit | ||
| CFXCorroflex | 380 | ATCU recirculation fan overload | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 381 | ATCU stage 1 compressor overload | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 385 | ATCU PLC input I14 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 387 | ATCU PLC input I16 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 39-1 | Heater bank E1 switched conductor | NO | — | Edit | ||
| CFXCorroflex | 39-2 | Heater bank E2 switched conductor | NO | — | Edit | ||
| CFXCorroflex | 39-3 | Heater bank E3 switched conductor | NO | — | Edit | ||
| CFXCorroflex | 392 | ATCU heater SSR control | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 393 | ATCU Y36 solenoid output | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 3L | ACC29 ATCU local phase 3 | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 4 | Incoming mains cable core for N; also reused as AC live/control feed after MCB6/MCB7 | NO | — | Edit | ||
| CFXCorroflex | 401 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 402 | Multi Solution Spray Motor M17 | YES — OPTIONAL I/OACC86 Multi Solution | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 403 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 404 | Multi Solution Spray Motor M18 | YES — OPTIONAL I/OACC86 Multi Solution | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 405 | Salt Spray 3 / Water Fog 3 | YES — OPTIONAL I/OAdditional spray pump output | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 406 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 407 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 41 | ATCU PLC relay output Q2 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 410 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 412 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 413 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 414 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 415 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 416 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 417 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 418 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 419 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 42 | ATCU PLC relay output Q3 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 422 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 424 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 425 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 426 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 427 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 428 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 429 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 43 | ATCU air circulation fan contactor | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 430 | Comp | YES — OPTIONAL I/OACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 431 | Salt Spray / Water Fog pump 3-4 motor interconnect | YESACC29-dependent additional spray pumps | Shown on circuits marked 'Fit With ACC29'. | Edit | ||
| CFXCorroflex | 432 | Salt Spray / Water Fog pump 3-4 motor interconnect | YESACC29-dependent additional spray pumps | Shown on circuits marked 'Fit With ACC29'. | Edit | ||
| CFXCorroflex | 433 | Salt Spray / Water Fog pump 3-4 motor interconnect | YESACC29-dependent additional spray pumps | Shown on circuits marked 'Fit With ACC29'. | Edit | ||
| CFXCorroflex | 434 | Salt Spray / Water Fog pump 3-4 motor interconnect | YESACC29-dependent additional spray pumps | Shown on circuits marked 'Fit With ACC29'. | Edit | ||
| CFXCorroflex | 435 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 436 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 437 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 438 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 439 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 44 | Interior illumination lamp circuit conductor | NO | — | Edit | ||
| CFXCorroflex | 440 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 441 | Salt Scrubber Valve | Exhaust salt scrubber valve | YESACC92 Exhaust salt scrubber | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 442 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 443 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 444 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 445 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 446 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 45 | Interior illumination relay command | Interior Illumination | YES — OPTIONAL I/OACC26 / Interior illumination | Named 'Interior Illumination' on the optional output card. Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 450 | Purge Valve for Salt Spray | Salt spray purge valve | YESACC30 Salt spray vertically down | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 46 | ATCU heater contactor command before OT2 | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 463 | Pressure Release Valve for Salt Spray | Salt spray pressure release valve | YESACC30 Salt spray vertically down | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 470 | GA - Fatal Error Warning | Guardian Angel fatal | YESACC05 Guardian Angel | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 471 | GA - Non-Fatal Error Warning | Guardian Angel non-fatal | YESACC05 Guardian Angel | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 472 | GA - System Healthy | Guardian Angel healthy | YESACC05 Guardian Angel | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 474 | Salt Spray 4 / Water Fog 4 | YES — OPTIONAL I/OAdditional spray pump output | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 475 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 48 | Blower heater control / optional output | Blower Heater | YES — OPTIONAL I/OBlower heater optional output | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 480 | Spraybar parked | Spraybar parked sensor signal | YESACC31 Oscillating spray bar, ACC31/1 or ACC31/2 | — | Edit | ||
| CFXCorroflex | 4L | ACC29 ATCU PLC/control AC live | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 50 | Wash Down Valve | Wall wash down valve | YESACC42 Wall wash down | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 500 | Oscillating Spray Bar Motor Engage | Oscillating spray bar motor engage | YESACC31 Oscillating spray bar | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 502 | Oscillating spray bar motor conductor | YESACC31 Oscillating spray bar | — | Edit | ||
| CFXCorroflex | 504 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | Corroflex Pump Output 3 | YESACC29-dependent additional spray pumps, Additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 51 | ATCU stage 1 bypass solenoid relay | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 519 | Air Saturator 2 / Water Fog / Salt Spray changeover solenoid circuit | Water Fog N/C solenoid / Salt Spray N/O solenoid | NO | — | Edit | ||
| CFXCorroflex | 52 | ATCU stage 2 cool solenoid relay | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 53 | ATCU stage 2 bypass solenoid relay | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 537 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 538 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 539 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 54-1 | Immersion heater switched conductor | NO | — | Edit | ||
| CFXCorroflex | 54-2 | Immersion heater switched conductor | NO | — | Edit | ||
| CFXCorroflex | 54-3 | Immersion heater switched conductor | NO | — | Edit | ||
| CFXCorroflex | 540 | Additional Salt Spray / Water Fog pump motor/F2V interconnect | YESACC29-dependent additional spray pumps | Shown in the additional-pumps circuits with ACC29 annotations. | Edit | ||
| CFXCorroflex | 541 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 55 | ATCU PLC relay output Q13 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 560 | De-Humidify | ATCU DEHUMID input | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 563 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 564 | 8-channel analogue output to optional pump/F2V drive | YES — OPTIONAL I/OACC29 / ACC86 additional pump drives | Channel function depends on the fitted pump/option. | Edit | ||
| CFXCorroflex | 57 | ATCU heater contactor command after OT2 | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 58 | Salt Spray Air Valve | Salt Spray Air Solenoid | YESAdditional spray pumps | Named on the sheet titled 'OPTIONAL OUTPUTS'. Optional if additional pumps are fitted. | Edit | ||
| CFXCorroflex | 580 | User Programmable Digital Output 3 relay/contact conductor | YESUser Programmable Digital Output 3 | — | Edit | ||
| CFXCorroflex | 581 | User Programmable Digital Output 3 relay/contact conductor | YESUser Programmable Digital Output 3 | — | Edit | ||
| CFXCorroflex | 582 | User Programmable Digital Output 3 relay/contact conductor | YESUser Programmable Digital Output 3 | — | Edit | ||
| CFXCorroflex | 583 | User Programmable Digital Output 3 relay/contact conductor | YESUser Programmable Digital Output 3 | — | Edit | ||
| CFXCorroflex | 59 | Base fill valve | Base fill | NO | — | Edit | ||
| CFXCorroflex | 598 | ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M19 | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 60 | High Water Warning Lamp | High water lamp | YESACC66 High water lamp | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 601 | ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M20 | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 604 | ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M21 | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 608 | ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M22 | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 612 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 614 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 615 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 616 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 617 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 618 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 619 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 620 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 63 | Over-temperature thermostat O/T8 | O/T8 input | NO | — | Edit | ||
| CFXCorroflex | 637 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 638 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 639 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 64 | Over-temperature thermostat O/T7 | O/T7 input | NO | — | Edit | ||
| CFXCorroflex | 640 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 641 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 642 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 643 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 644 | ACC86 Multi Solution pump / F2V / motor interconnect | YESACC86 Multi Solution | — | Edit | ||
| CFXCorroflex | 650 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 651 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 652 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 653 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 654 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 655 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 656 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 657 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 658 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 659 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 660 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 661 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 662 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 663 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 668 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 669 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 670 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 671 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 672 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 673 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 674 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 675 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 676 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 677 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 678 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 679 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 68 | Cool | ATCU COOL input | YESACC29 Refrigeration & humidity control | Named on the sheet titled 'OPTIONAL OUTPUTS'. | Edit | ||
| CFXCorroflex | 680 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 681 | ECC1 additional atomiser pump / F2V / motor interconnect | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 686 | ECC1 Pump 1 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 687 | ECC1 Pump 2 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 688 | ECC1 Pump 3 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 689 | ECC1 Pump 4 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 690 | ECC1 Pump 5 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 691 | ECC1 Pump 6 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 692 | ECC1 Pump 7 | YESACC25 ECC1 additional atomisers | — | Edit | ||
| CFXCorroflex | 74 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 75 | Salt Spray / Water Fog pump 1-2 motor or drive interconnect | NO | — | Edit | ||
| CFXCorroflex | 76 | Pump 1 pulse | NO | — | Edit | ||
| CFXCorroflex | 77 | Pump 2 pulse | NO | — | Edit | ||
| CFXCorroflex | 78 | ATCU PLC input I7 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 79 | ATCU heater contactor C4 auxiliary feedback | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 8 | 0 V DC common | 0 V return for optional output cards | Supply to PT100 / analogue cards including ACC34 option | Shared supply/return used by page 15 optional accessories | Shared supply/return to ACC42 / ACC46 / ACC29 accessories | Shared supply/return to ACC92 / ACC31 / ACC66 / ACC59 accessories | Shared power/supply conductor used by ACC30 / ACC102 circuits | Shared supply/return for page 19 optional accessories | Shared supply/return for ACC36 remote transmission and optional remote controls | YES — SHAREDOptional output cards, ACC34 optional PT100, ACC20 / ACC90 / additional pump options, ACC42 / ACC46 / ACC29, ACC92 / ACC31 / ACC66 / ACC59, ACC30 / ACC102, ACC39 / ACC47 / ACC05 / user outputs, ACC36 / Remote controls / Two-button canopy | Defined by the wire-identification table on page 1. ACC34 sensor leads are colour/terminal identified rather than assigned separate numeric wire IDs. | Edit | ||
| CFXCorroflex | 80 | Blower 1 tacho | NO | — | Edit | ||
| CFXCorroflex | 81 | Blower 2 tacho | NO | — | Edit | ||
| CFXCorroflex | 83 | ATCU stage 1 HP/LP signal contact | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 84 | ATCU stage 1 HP signal | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 85 | Base drain valve | Base drain | NO | — | Edit | ||
| CFXCorroflex | 86 | ATCU PLC input I15 - function not named | YESACC29 Refrigeration & humidity control | — | Edit | ||
| CFXCorroflex | 87 | Phase feed after MCB30 to optional ATCU power pages | NO | — | Edit | ||
| CFXCorroflex | 870 | ACC29 ATCU phase after MCB21 | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 88 | Phase feed after MCB30 to optional ATCU power pages | NO | — | Edit | ||
| CFXCorroflex | 880 | ACC29 ATCU phase after MCB21 | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 887 | Phase feed from X1 to MCB30 / MCB1 | NO | — | Edit | ||
| CFXCorroflex | 888 | Phase feed from X1 to MCB30 / MCB2 | NO | — | Edit | ||
| CFXCorroflex | 8L | ACC29 ATCU 0 V DC | YESACC29 Refrigeration & humidity control | Pages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40). | Edit | ||
| CFXCorroflex | 91 | Low air pressure | Low-air input | NO | — | Edit | ||
| CFXCorroflex | 96 | Air saturator heater inhibit | Air saturator inhibit input | NO | — | Edit | ||
| CFXCorroflex | 97-1 | Blower E6 circuit conductor | NO | — | Edit | ||
| CFXCorroflex | 97-2 | Blower E7 circuit conductor | NO | — | Edit | ||
| CFXCorroflex | 98 | Blower over-temperature thermostat O/T3 circuit | NO | — | Edit | ||
| CFXCorroflex | E | Supply earth / protective earth | NO | Defined by the wire-identification table on page 1. | Edit | ||
| CFXCorroflex | L1 | Mains supply phase L1 | NO | Defined by the wire-identification table on page 1. | Edit | ||
| CFXCorroflex | L2 | Mains supply phase L2 | NO | Defined by the wire-identification table on page 1. | Edit | ||
| CFXCorroflex | L3 | Mains supply phase L3 | NO | Defined by the wire-identification table on page 1. | Edit | ||
| CFXCorroflex | N | Mains neutral | NO | Defined by the wire-identification table on page 1. | Edit | ||
| CFXCorroflex | N1 | Neutral before RCD / X1 | NO | — | Edit | ||
| CFXCorroflex | N2 | Neutral after RCD / X1 distribution | NO | — | Edit | ||
| CFXCorroflex | NV4 | COMPRESSED AIR RELAYBRIDGE COVER | — | — | Edit | ||
| CYCLICCC2600IP | 1 | Incoming main-supply cable/core marking on L1 | NO | Shown beside the L1 conductor; may be a cable core number rather than the global wire-number scheme. | Edit | ||
| CYCLICCC2600IP | 10 | O/T 1 over-temperature input | NO | — | Edit | ||
| CYCLICCC2600IP | 100 | Filtered mains phase feed from Z1; also feeds accessory branches | YES — SHAREDMultiple option/accessory branches — shared mains feed/return | — | Edit | ||
| CYCLICCC2600IP | 1000 | Switched heater mains phase from contactor K30 | NO | — | Edit | ||
| CYCLICCC2600IP | 1001 | Switched heater mains phase from contactor K30 | NO | — | Edit | ||
| CYCLICCC2600IP | 1002 | Switched heater mains phase from contactor K30 | NO | — | Edit | ||
| CYCLICCC2600IP | 1004 | Air-saturator heater protected live branch after MCB8 | NO | — | Edit | ||
| CYCLICCC2600IP | 101 | Filtered mains phase feed from Z1; feeds 24 V PSU / ACC30 branch | YES — SHAREDACC30 — Salt Spray Vertically Down; shared mains feed | — | Edit | ||
| CYCLICCC2600IP | 102 | Filtered mains phase feed from Z1; used by heater/option branches | YES — SHAREDLiquid Immersion Reservoir / Interface / other option branches — shared mains feed | — | Edit | ||
| CYCLICCC2600IP | 11 | O/T 2 over-temperature input | NO | — | Edit | ||
| CYCLICCC2600IP | 113 | O/T 6 to blower E5/B interconnect (2000L/2600L) | NO | — | Edit | ||
| CYCLICCC2600IP | 1133 | User programmable digital output 2 command | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 115 | Pump 2 F2V2 / K6 drive interconnect | NO | — | Edit | ||
| CYCLICCC2600IP | 116 | Pump 2 F2V2 / K6 drive interconnect | NO | — | Edit | ||
| CYCLICCC2600IP | 117 | ACC46 SO2 fill solenoid Y26 switched feed from relay K102 | YESACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 1180 | User programmable digital output 2 relay K21 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 1181 | User programmable digital output 2 relay K21 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 1182 | User programmable digital output 2 relay K21 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 1183 | User programmable digital output 2 relay K21 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 123 | ACC20 full switch input | YESACC20 — Waste Water Trough & Pump System | — | Edit | ||
| CYCLICCC2600IP | 1233 | User programmable digital output 4 command | YESACC34 — Liquid Immersion Reservoir / Interface; User Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 125 | ACC92 scrubber flow input | YESACC92 — Exhaust Salt Scrubber | — | Edit | ||
| CYCLICCC2600IP | 125_1 | Air pressure 1 switch input | YES | Shared with ACC92 | Edit | ||
| CYCLICCC2600IP | 1265 | ACC29 butterfly valve | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 132 | Pump M2 red motor lead | NO | — | Edit | ||
| CYCLICCC2600IP | 133 | User programmable digital output 1 command | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 134 | Spot cooler relay K27 coil +24 V feed | YESACC90 — Spot Cooler | Revision M states K27 A1 is permanently 24 V. | Edit | ||
| CYCLICCC2600IP | 139 | ACC47 rapid-transition extra heater-mat feed | YESACC47 — Rapid Transition / Blower Ball Valve | — | Edit | ||
| CYCLICCC2600IP | 14 | Moist air solenoid Y4 | NO | — | Edit | ||
| CYCLICCC2600IP | 140 | Salt solution consumption sensor ACC102 signal (black lead) | YESACC102 — Salt Solution Consumption Sensor | — | Edit | ||
| CYCLICCC2600IP | 144 | Interior illumination protected live feed through MCB12/K17 | YESACC26 — Interior Illumination | — | Edit | ||
| CYCLICCC2600IP | 147 | Salt tank low water alarm | YESACC59 — Salt Tank Low Water Alarm option family | — | Edit | ||
| CYCLICCC2600IP | 148 | BV3 blower ball-valve position-switch interconnect (2000L+) | YESACC39 — Blower Ball Valve; ACC47 — Rapid Transition / Blower Ball Valve | — | Edit | ||
| CYCLICCC2600IP | 1580 | User programmable digital output 4 relay K33 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 1581 | User programmable digital output 4 relay K33 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 1582 | User programmable digital output 4 relay K33 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 1583 | User programmable digital output 4 relay K33 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 159 | Liquid-immersion header-tank / N-trap valve control bus | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 164 | ATCU OK status | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 170 | Blower ball-valve position input | YESACC39 — Blower Ball Valve; ACC47 — Rapid Transition / Blower Ball Valve | — | Edit | ||
| CYCLICCC2600IP | 173 | Water LOW input | NO | — | Edit | ||
| CYCLICCC2600IP | 174 | Liquid-immersion LOW indicator/control line via X6 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 177 | ACC29 pump changeover/selection relay coil enable | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 18 | Emergency stop input | NO | — | Edit | ||
| CYCLICCC2600IP | 180 | User programmable digital output 1 relay K20 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 181 | User programmable digital output 1 relay K20 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 182 | User programmable digital output 1 relay K20 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 183 | User programmable digital output 1 relay K20 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 189 | Phase conductor after MCB26, before EMI/filter Z1 | NO | — | Edit | ||
| CYCLICCC2600IP | 1891 | Phase conductor after 25 A RCD, before MCB26 | NO | — | Edit | ||
| CYCLICCC2600IP | 19 | Canopy opened input | NO | — | Edit | ||
| CYCLICCC2600IP | 191 | Spot cooler power branch after MCB15 | YESACC90 — Spot Cooler | — | Edit | ||
| CYCLICCC2600IP | 197 | Liquid-immersion fill/control bus; also K14 command path | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 198 | Heater over-temperature count signal | NO | — | Edit | ||
| CYCLICCC2600IP | 2 | Incoming main-supply cable/core marking on L2 | AC neutral/common return used throughout heater and option circuits | NO | YES — SHAREDMultiple option/accessory branches — shared mains feed/return | This conflicts with other page-2+ uses of '2' as neutral/common, so treat as local/core marking. | Also appears as an incoming cable/core label on page 2; do not assume global uniqueness without page context. | Edit | ||
| CYCLICCC2600IP | 20 | Auto fill solenoid Y1 | NO | — | Edit | ||
| CYCLICCC2600IP | 204 | Empty-base pump motor M8 lead | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 205 | Empty-base pump motor M8 lead | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 206 | Fill-base pump motor M7 lead via relay K14 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 207 | Fill-base pump motor M7 lead via relay K14 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 21 | Air saturator FULL optical sensor | NO | — | Edit | ||
| CYCLICCC2600IP | 210 | Heat command | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 211 | Chamber full liquid-immersion switch SW21 signal | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 212 | Chamber liquid-immersion O/T13 signal | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 213 | Remote PAUSE input | YESRemote START/STOP/PAUSE/UNPAUSE accessory interface | — | Edit | ||
| CYCLICCC2600IP | 214 | Remote UNPAUSE input | YESRemote START/STOP/PAUSE/UNPAUSE accessory interface | — | Edit | ||
| CYCLICCC2600IP | 215 | Remote START input | YESRemote START/STOP/PAUSE/UNPAUSE accessory interface | — | Edit | ||
| CYCLICCC2600IP | 216 | Remote STOP input | YESRemote START/STOP/PAUSE/UNPAUSE accessory interface | — | Edit | ||
| CYCLICCC2600IP | 217 | Two-button canopy option input | YESTwo-button canopy option | — | Edit | ||
| CYCLICCC2600IP | 22 | Air saturator LOW optical sensor | NO | — | Edit | ||
| CYCLICCC2600IP | 220 | Chart recorder B5 brown lead | YESChart recorder option | — | Edit | ||
| CYCLICCC2600IP | 221 | Chart recorder B5 white lead | YESChart recorder option | — | Edit | ||
| CYCLICCC2600IP | 233 | User programmable digital output 3 command | YESACC34 — Liquid Immersion Reservoir / Interface; User Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 236 | Canopy open solenoid circuit | NO | — | Edit | ||
| CYCLICCC2600IP | 237 | Canopy close solenoid circuit | NO | — | Edit | ||
| CYCLICCC2600IP | 24 | +24 V DC control rail | YES — SHAREDMultiple optional accessories — shared DC control rail | — | Edit | ||
| CYCLICCC2600IP | 241 | ACC46 SICK safety-relay input/internal safety circuit line | YESACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 242 | ACC46 SICK safety-relay output/reset internal line | YESACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 244 | ACC46 safety reset circuit line | YESACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 248 | ACC46 purge timer / canopy-open-safe PLC input signal | YESACC46 — Sulphur Dioxide Dosing | Page 7 calls it ACC46 PURGE TIMER; page 26 labels the same wire as PLC I2 CANOPY OPEN. | Edit | ||
| CYCLICCC2600IP | 249 | SO2 dose feedback | YESACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 25 | Open canopy command | NO | — | Edit | ||
| CYCLICCC2600IP | 250 | K16 T1 to immersion heater E6/A | Air bar / ACC46 purge air bar output | YES | YES — SHAREDACC34 — Liquid Immersion Reservoir / Interface | ACC46 — Sulphur Dioxide Dosing; standard Air Bar output | Same wire number is also used for Air Bar on pages 4/7/26; page context is essential. | Edit | ||
| CYCLICCC2600IP | 252 | Salt spray motor run | YESACC30 — Salt Spray Vertically Down | — | Edit | ||
| CYCLICCC2600IP | 253 | K16 T2 to immersion heater E6/B | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 254 | K16 T3 to immersion heater E6/C | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 255 | K15 to K16/A L1 interconnect | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 256 | K15 to K16/B L2 interconnect | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 257 | K15 to K16/C L3 interconnect | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 258 | K15 coil A1 control line | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 259 | K15 coil A2 control line | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 26 | Dry air solenoid Y3 | NO | — | Edit | ||
| CYCLICCC2600IP | 260 | O/T15 / base-fill thermostat chain | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 261 | O/T16 / base-fill thermostat chain | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 262 | O/T12 / base-fill thermostat chain | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 265 | Run command | YESACC29 — Refrigeration & Humidity Control / ATCU; ACC112 — MIDI Dehumidification Unit; ACC125 — ACTU interface option | — | Edit | ||
| CYCLICCC2600IP | 27 | Close canopy command | NO | — | Edit | ||
| CYCLICCC2600IP | 270 | TEMC036 terminal 1 control loop | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 271 | K16 coil A1 / TEMC036 terminal 16 control line | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 272 | K16 coil A2 / TEMC036 terminal 3 control line | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 275 | Liquid-immersion L1 after MCB12, into contactor K15 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 276 | Liquid-immersion L2 after MCB13, into contactor K15 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 277 | Liquid-immersion L3 after MCB14 / controller supply bus | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 28 | Canopy closed input / ACC46 canopy-closed safety signal | YES — SHAREDACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 282 | Liquid-immersion 3-phase L1 after isolator Q2, before MCB12 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 283 | Liquid-immersion 3-phase L2 after isolator Q2, before MCB13 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 284 | Liquid-immersion 3-phase L3 after isolator Q2, before MCB14 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 286 | Humidify command | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 289 | P_Fill command | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 3 | Incoming main-supply cable/core marking on L3 | NO | Shown beside the L3 conductor; may be a cable core number rather than the global wire-number scheme. | Edit | ||
| CYCLICCC2600IP | 31 | Pump M1 black motor lead | NO | — | Edit | ||
| CYCLICCC2600IP | 311 | Air curtain | YESACC96 — Air Curtain pneumatic option | — | Edit | ||
| CYCLICCC2600IP | 32 | Pump M2 black motor lead | NO | — | Edit | ||
| CYCLICCC2600IP | 320 | Cabinet PT100, white lead | NO | — | Edit | ||
| CYCLICCC2600IP | 321 | Cabinet PT100, red lead | NO | — | Edit | ||
| CYCLICCC2600IP | 322 | Cabinet PT100, red lead | NO | — | Edit | ||
| CYCLICCC2600IP | 323 | Air saturator PT100, white lead | NO | — | Edit | ||
| CYCLICCC2600IP | 324 | Air saturator PT100, red lead | NO | — | Edit | ||
| CYCLICCC2600IP | 325 | Air saturator PT100, red lead | NO | — | Edit | ||
| CYCLICCC2600IP | 326 | Psychrometric wet PT100, white lead | NO | — | Edit | ||
| CYCLICCC2600IP | 327 | Psychrometric wet PT100, orange lead | NO | — | Edit | ||
| CYCLICCC2600IP | 328 | Psychrometric wet PT100, red lead | NO | — | Edit | ||
| CYCLICCC2600IP | 329 | Psychrometric dry PT100, yellow lead | NO | — | Edit | ||
| CYCLICCC2600IP | 33 | Blower ball valve(s) with position switch(es) | YESACC39 — Blower Ball Valve; ACC47 — Rapid Transition / Blower Ball Valve | — | Edit | ||
| CYCLICCC2600IP | 330 | Psychrometric dry PT100, green lead | NO | — | Edit | ||
| CYCLICCC2600IP | 331 | Psychrometric dry PT100, brown lead | NO | — | Edit | ||
| CYCLICCC2600IP | 332 | ACC34 option PT100, white lead | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 333 | ACC34 option PT100, red lead | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 334 | ACC34 option PT100, red lead | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 34 | Buzzer | NO | — | Edit | ||
| CYCLICCC2600IP | 35 | Air saturator heater E2 load-side conductor to relay K1 | NO | — | Edit | ||
| CYCLICCC2600IP | 352 | ACC30 vertically-down salt-spray motor M9 switched motor lead | YESACC30 — Salt Spray Vertically Down | — | Edit | ||
| CYCLICCC2600IP | 353 | ACC30 relay K19 switched supply bus | YESACC30 — Salt Spray Vertically Down | — | Edit | ||
| CYCLICCC2600IP | 36 | Air saturator heater control | NO | — | Edit | ||
| CYCLICCC2600IP | 37 | Chamber heater control | NO | — | Edit | ||
| CYCLICCC2600IP | 374 | ACC20 run-switch return / waste-water trough interface | YESACC20 — Waste Water Trough & Pump System | — | Edit | ||
| CYCLICCC2600IP | 375 | ACC20 waste-water trough motor/relay interconnect | YESACC20 — Waste Water Trough & Pump System | — | Edit | ||
| CYCLICCC2600IP | 377 | Sulphur dioxide supply valve | YESACC46 — Sulphur Dioxide Dosing | — | Edit | ||
| CYCLICCC2600IP | 38 | Immersion heater control | NO | — | Edit | ||
| CYCLICCC2600IP | 39 | Chamber heater mat load-side conductor | NO | — | Edit | ||
| CYCLICCC2600IP | 4 | Incoming main-supply cable/core marking on N | 24 V power-supply AC live feed after MCB6; also accessory live feed | NO | YES — SHAREDMultiple option/accessory branches — shared mains feed/return | This conflicts with later use of '4' as an AC live accessory/PSU feed, so treat as local/core marking. | The drawing also shows 1-4 as incoming cable core labels; context matters. | Edit | ||
| CYCLICCC2600IP | 401 | 8-channel analogue output card channel 3 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 402 | Multi-solution spray motor M16 command | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 403 | 8-channel analogue output card channel 1 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 404 | Multi-solution spray motor M17 command | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 405 | Additional atomiser motor M10 command | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 406 | 8-channel analogue output card channel 4 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 407 | 8-channel analogue output card channel 2 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 410 | ACC25 additional atomiser M10 / F2V3 / relay K23 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 412 | ACC25 additional atomiser M10 / F2V3 / relay K23 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 413 | ACC86 multi-solution M16/M17 / F2V9-F2V10 / relay K28 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 414 | ACC86 multi-solution M16/M17 / F2V9-F2V10 / relay K28 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 415 | ACC25 additional atomiser M11 / F2V4 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 416 | ACC86 multi-solution M17 / F2V10 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 417 | ACC25 additional atomiser M11 / F2V4 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 418 | ACC86 multi-solution M17 / F2V10 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 419 | ACC32 water-fog M12/M13 / F2V5-F2V6 / relay K24 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 422 | ACC32 water-fog M12/M13 / F2V5-F2V6 / relay K24 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 424 | ACC32 water-fog M13 / F2V6 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 425 | ACC32 water-fog M13 / F2V6 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 426 | ACC86 multi-solution M14/M15 / F2V7-F2V8 / relay K26 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 427 | ACC86 multi-solution M14/M15 / F2V7-F2V8 / relay K26 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 428 | ACC86 multi-solution M15 / F2V8 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 429 | ACC86 multi-solution M15 / F2V8 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 430 | Compressor command (Comp) | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 431 | ACC25 additional atomiser M10 / F2V3 / relay K23 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 432 | ACC25 additional atomiser M10 / F2V3 / relay K23 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 433 | ACC25 additional atomiser M10 / F2V3 / relay K23 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 434 | ACC25 additional atomiser M10 / F2V3 / relay K23 interconnect | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 435 | ACC32 water-fog M12/M13 / F2V5-F2V6 / relay K24 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 436 | ACC32 water-fog M12/M13 / F2V5-F2V6 / relay K24 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 437 | ACC32 water-fog M12/M13 / F2V5-F2V6 / relay K24 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 438 | ACC32 water-fog M12/M13 / F2V5-F2V6 / relay K24 interconnect | YESACC32 — Water Fog | — | Edit | ||
| CYCLICCC2600IP | 439 | ACC86 multi-solution M14/M15 / F2V7-F2V8 / relay K26 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 44 | Interior illumination lamp P10 switched lead | YESACC26 — Interior Illumination | — | Edit | ||
| CYCLICCC2600IP | 440 | ACC86 multi-solution M14/M15 / F2V7-F2V8 / relay K26 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 441 | Salt scrubber valve | YESACC92 — Exhaust Salt Scrubber | — | Edit | ||
| CYCLICCC2600IP | 442 | ACC86 multi-solution M14/M15 / F2V7-F2V8 / relay K26 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 443 | ACC86 multi-solution M14/M15 / F2V7-F2V8 / relay K26 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 444 | ACC86 multi-solution M16/M17 / F2V9-F2V10 / relay K28 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 445 | ACC86 multi-solution M16/M17 / F2V9-F2V10 / relay K28 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 446 | ACC86 multi-solution M16/M17 / F2V9-F2V10 / relay K28 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 447 | ACC86 multi-solution M16/M17 / F2V9-F2V10 / relay K28 interconnect | YESACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 45 | Interior illumination relay command | YESACC26 — Interior Illumination | — | Edit | ||
| CYCLICCC2600IP | 450 | Purge valve for salt spray | YESACC30 — Salt Spray Vertically Down | — | Edit | ||
| CYCLICCC2600IP | 463 | Pressure release valve for salt spray | YESACC30 — Salt Spray Vertically Down | — | Edit | ||
| CYCLICCC2600IP | 470 | Guardian Angel - fatal error warning | YESACC05 — Guardian Angel | — | Edit | ||
| CYCLICCC2600IP | 471 | Guardian Angel - non-fatal error warning | YESACC05 — Guardian Angel | — | Edit | ||
| CYCLICCC2600IP | 472 | Guardian Angel - system healthy | YESACC05 — Guardian Angel | — | Edit | ||
| CYCLICCC2600IP | 474 | Additional atomiser motor M11 command | YESACC25 — ECC1 Additional Atomisers | — | Edit | ||
| CYCLICCC2600IP | 475 | 8-channel analogue output card channel 0 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 48 | Blower heater control | YES — OPTIONAL I/OPLCC015-1 optional digital-output card (blower heater connection) | — | Edit | ||
| CYCLICCC2600IP | 480 | Spraybar parked sensor | YESACC31 — Oscillating Spray Bar | — | Edit | ||
| CYCLICCC2600IP | 5 | Pump M1 red motor lead | NO | — | Edit | ||
| CYCLICCC2600IP | 50 | Wash down valve | YESACC42 — Wall Wash Down | — | Edit | ||
| CYCLICCC2600IP | 500 | Oscillating spray bar motor engage | YESACC31 — Oscillating Spray Bar | — | Edit | ||
| CYCLICCC2600IP | 502 | Oscillating spray-bar motor M19 drive lead | YESACC31 — Oscillating Spray Bar | — | Edit | ||
| CYCLICCC2600IP | 54 | Immersion heater E7 load-side conductor to relay K10 | NO | — | Edit | ||
| CYCLICCC2600IP | 560 | De-humidify command | YESACC29 — Refrigeration & Humidity Control / ATCU; ACC112 — MIDI Dehumidification Unit; ACC125 — ACTU interface option | — | Edit | ||
| CYCLICCC2600IP | 563 | 8-channel analogue output card channel 6 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 564 | 8-channel analogue output card channel 5 / additional-pump speed-control bus | YESACC25 — ECC1 Additional Atomisers; ACC32 — Water Fog; ACC86 — Multi Solution Spray | — | Edit | ||
| CYCLICCC2600IP | 58 | Salt spray air valve | YESAdditional pump facility — optional salt-spray air solenoid | — | Edit | ||
| CYCLICCC2600IP | 580 | User programmable digital output 3 relay K32 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 581 | User programmable digital output 3 relay K32 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 582 | User programmable digital output 3 relay K32 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 583 | User programmable digital output 3 relay K32 / X14 interconnect | YESUser Programmable Digital Output option | — | Edit | ||
| CYCLICCC2600IP | 59 | Base fill | NO | — | Edit | ||
| CYCLICCC2600IP | 6 | RH1 humidity sensor signal, white lead | NO | — | Edit | ||
| CYCLICCC2600IP | 60 | High water warning lamp | YESACC66 — High Water Warning Lamp | — | Edit | ||
| CYCLICCC2600IP | 63 | O/T 8 over-temperature input | NO | — | Edit | ||
| CYCLICCC2600IP | 64 | O/T 7 over-temperature input | NO | — | Edit | ||
| CYCLICCC2600IP | 65 | O/T 12 over-temperature input | NO | — | Edit | ||
| CYCLICCC2600IP | 68 | Cool command | YESACC29 — Refrigeration & Humidity Control / ATCU | — | Edit | ||
| CYCLICCC2600IP | 71 | Liquid-immersion interface status/control line via X6 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 72 | Liquid-immersion HIGH indicator/control line via X6 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 73 | Liquid-immersion OK indicator/control line via X6 | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 74 | Pump 1 F2V1 / K6 drive interconnect | NO | — | Edit | ||
| CYCLICCC2600IP | 75 | Pump 1 F2V1 / K6 drive interconnect | NO | — | Edit | ||
| CYCLICCC2600IP | 76 | Pump 1 pulse | NO | — | Edit | ||
| CYCLICCC2600IP | 77 | Pump 2 pulse; reused by ACC46 as PLC Q1 SO2 demand/timer input | YESACC46 — Sulphur Dioxide Dosing | Function depends on option configuration. | Edit | ||
| CYCLICCC2600IP | 8 | 0 V DC control rail | YES — SHAREDMultiple optional accessories — shared DC control rail | — | Edit | ||
| CYCLICCC2600IP | 85 | Base drain (close) | NO | — | Edit | ||
| CYCLICCC2600IP | 87 | Phase conductor after MCB26, before EMI/filter Z1 | NO | — | Edit | ||
| CYCLICCC2600IP | 871 | Phase conductor after 25 A RCD, before MCB26 | NO | — | Edit | ||
| CYCLICCC2600IP | 88 | Phase conductor after MCB26, before EMI/filter Z1 | NO | — | Edit | ||
| CYCLICCC2600IP | 881 | Phase conductor after 25 A RCD, before MCB26 | NO | — | Edit | ||
| CYCLICCC2600IP | 9 | Air pressure sensor S5 signal, black lead | NO | — | Edit | ||
| CYCLICCC2600IP | 91 | Low air input | NO | — | Edit | ||
| CYCLICCC2600IP | 92 | Liquid-immersion base-empty valve / relay control bus | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 93 | Liquid-immersion heater/control relay K13 command | YESACC34 — Liquid Immersion Reservoir / Interface | — | Edit | ||
| CYCLICCC2600IP | 96 | Air saturator heater inhibit | NO | — | Edit | ||
| CYCLICCC2600IP | 97 | Blower heater load-side conductor to relay K3 | NO | — | Edit | ||
| CYCLICCC2600IP | 98 | O/T 3 to blower E5/A interconnect | NO | — | Edit | ||
| CYCLICCC2600IP | C1 | Cylinder 1 | — | — | Edit | ||
| CYCLICCC2600IP | C2 | Cylinder 2 | — | — | Edit | ||
| CYCLICCC2600IP | E | Supply earth | NO | — | Edit | ||
| CYCLICCC2600IP | L1 | Mains supply phase L1 | NO | — | Edit | ||
| CYCLICCC2600IP | L2 | Mains supply phase L2 | NO | — | Edit | ||
| CYCLICCC2600IP | L3 | Mains supply phase L3 | NO | — | Edit | ||
| CYCLICCC2600IP | M1 | Pump 1 | — | — | Edit | ||
| CYCLICCC2600IP | M2 | Pump 2 | — | — | Edit | ||
| CYCLICCC2600IP | MS1 | Compressed-air service | — | — | Edit | ||
| CYCLICCC2600IP | N | Mains neutral | NO | — | Edit | ||
| CYCLICCC2600IP | N2 | Neutral conductor after 25 A RCD / through filter path | NO | — | Edit | ||
| CYCLICCC2600IP | NRV1 | Non-return valve | — | — | Edit | ||
| CYCLICCC2600IP | NRV2 | Non-return valve | — | — | Edit | ||
| CYCLICCC2600IP | NRV3 | Non-return valve | — | — | Edit | ||
| CYCLICCC2600IP | NRV4 | Non-return valve | — | — | Edit | ||
| CYCLICCC2600IP | NRV5 | Non-return valve | — | — | Edit | ||
| CYCLICCC2600IP | NV1 | Valve | — | — | Edit | ||
| CYCLICCC2600IP | NV2 | Valve | — | — | Edit | ||
| CYCLICCC2600IP | NV3 | Valve | — | — | Edit | ||
| CYCLICCC2600IP | P0 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P1 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P10 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P2 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P29 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P3 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P30 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P31 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P32 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P39 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P4 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P5 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P6 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P7 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P8 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | P9 | Pneumatic line / port identifier | — | — | Edit | ||
| CYCLICCC2600IP | PE symbol | Cabinet earth | NO | — | Edit | ||
| CYCLICCC2600IP | PG1 | Pressure gauge 1 | — | — | Edit | ||
| CYCLICCC2600IP | PR1 | Pressure regulator 1 | — | — | Edit | ||
| CYCLICCC2600IP | PR2 | Pressure regulator 2 | — | — | Edit | ||
| CYCLICCC2600IP | PR3 | Pressure regulator 3 | — | — | Edit | ||
| CYCLICCC2600IP | PR4 | Pressure regulator 4 | — | — | Edit | ||
| CYCLICCC2600IP | PR5 | Pressure regulator 5 | — | — | Edit | ||
| CYCLICCC2600IP | S10 | Sensor / switch | — | — | Edit | ||
| CYCLICCC2600IP | S11 | Pneumatic sensor switch | — | — | Edit | ||
| CYCLICCC2600IP | S5 | Air pressure sensor | — | PNEC069 | Edit | ||
| CYCLICCC2600IP | S7 | Sensor / switch | — | — | Edit | ||
| CYCLICCC2600IP | S8 | Sensor / switch | — | — | Edit | ||
| CYCLICCC2600IP | S9 | Sensor / switch | — | — | Edit | ||
| CYCLICCC2600IP | SV1 | Solenoid valve | — | — | Edit | ||
| CYCLICCC2600IP | Y1 | Auto fill | — | — | Edit | ||
| CYCLICCC2600IP | Y10 | Canopy open | — | — | Edit | ||
| CYCLICCC2600IP | Y11 | Canopy close | — | — | Edit | ||
| CYCLICCC2600IP | Y2 | Purge valve on pneumatic schematic | — | — | Edit | ||
| CYCLICCC2600IP | Y26 | SO2 fill (optional) | — | — | Edit | ||
| CYCLICCC2600IP | Y3 | Dry air | — | — | Edit | ||
| CYCLICCC2600IP | Y33 | Air curtain solenoid | — | Optional | Edit | ||
| CYCLICCC2600IP | Y4 | Moist air | — | — | Edit | ||
| CYCLICCC2600IP | Y5 | Pneumatic valve / actuator | — | — | Edit | ||
| CYCLICCC2600IP | Y6 | Pneumatic valve / actuator | — | — | Edit | ||
| CYCLICCC2600IP | Y60 | Purge solenoid | — | Electrical output sheet tag | Edit | ||
| CYCLICCC2600IP | Y9 | Pneumatic valve / actuator | — | — | Edit | ||
| Salt Spray Premium120 - 1300 | 1 | Cabinet mains live distribution feed from the mains filter / RCBO path to K30 L1 and page 3 circuits | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | Edit | ||
| Salt Spray Premium120 - 1300 | 10 | O/T 1 over-temperature input | NO | Page 4 shows wire 10 from the O/T chain to the PLC. | Edit | ||
| Salt Spray Premium120 - 1300 | 1004 | Air-saturator heater branch between K1 and MCB4 | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 101 | Switched mains live bus from K30 feeding heater relay contacts | NO | Feeds K10 and K2 directly and K1 through MCB4. | Edit | ||
| Salt Spray Premium120 - 1300 | 107 | Cabinet heater E4/B model-specific load conductor | NO | Shown for models B, C, D, F, G, J, K and L. | Edit | ||
| Salt Spray Premium120 - 1300 | 108 | Cabinet heater E4/C model-specific load conductor | NO | Shown for models B, C, D, J, K and L. | Edit | ||
| Salt Spray Premium120 - 1300 | 11 | O/T 2 input and over-temperature safety link to K30 | NO | Wire 11 also connects the O/T chain to relay K30 A1 on page 3. | Edit | ||
| Salt Spray Premium120 - 1300 | 123 | ACC20 full-switch input | YESACC20 — option | — | Edit | ||
| Salt Spray Premium120 - 1300 | 125 | ACC92 scrubber-flow input | YESACC92 — Scrubber Flow Meter | — | Edit | ||
| Salt Spray Premium120 - 1300 | 132 | Pump M2 red motor lead between F2V2 and PERC010 | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 14 | Moist air solenoid Y4 command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 144 | Internal-illumination protected live feed from MCB3 to K17 contacts | YESInternal Illumination (OPTION) | — | Edit | ||
| Salt Spray Premium120 - 1300 | 147 | Salt-tank low-water alarm input | NO — MODEL DEPENDENT | Page 7 states NOT FITTED TO A AND I MODELS; it is not explicitly labelled as an option in this issue. | Edit | ||
| Salt Spray Premium120 - 1300 | 15 | Switched mains live conductor between Q1 and the RCBO | NO | Used in both mains-filter arrangements. | Edit | ||
| Salt Spray Premium120 - 1300 | 16 | Protected neutral interconnect from the RCBO to ELEC516.1 | NO | Shown in the non-integral mains-filter arrangement. | Edit | ||
| Salt Spray Premium120 - 1300 | 163 | High-water input | NO — MODEL DEPENDENT | Page 4 shows the high-water optical sensor circuit fitted to models A and I only. | Edit | ||
| Salt Spray Premium120 - 1300 | 173 | Water LOW input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 18 | Emergency-stop status input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 19 | Canopy opened switch input | NO | Page 4 shows the pneumatic sensor-switch circuit. | Edit | ||
| Salt Spray Premium120 - 1300 | 190 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-7 of this issue. | Edit | ||
| Salt Spray Premium120 - 1300 | 2 | Cabinet mains neutral / common return to heater and accessory circuits | YES — SHAREDInternal Illumination option — shared mains return | Also returns the optional internal-illumination lamp circuit. | Edit | ||
| Salt Spray Premium120 - 1300 | 20 | Air-saturator auto-fill solenoid Y1 command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 200 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-7 of this issue. | Edit | ||
| Salt Spray Premium120 - 1300 | 2000 | Immersion-heater neutral-side conductor shown at E7/A | NO | Page 1 revision F references neutral wire 2000; later revision G says neutral is no longer through the contactor. Page 3 still labels E7/A with 2000. | Edit | ||
| Salt Spray Premium120 - 1300 | 21 | Air-saturator FULL optical sensor input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 22 | Air-saturator LOW optical sensor input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 236 | Canopy-open solenoid conductor after the emergency-stop contacts | NO | Connects S4 to the canopy OPEN solenoid Y10. | Edit | ||
| Salt Spray Premium120 - 1300 | 237 | Canopy-close solenoid conductor after the emergency-stop contacts | NO | Connects S4 to the canopy CLOSE solenoid Y11. | Edit | ||
| Salt Spray Premium120 - 1300 | 24 | +24 V DC control rail | YES — SHAREDHUMA030 RH1; ACC20; ACC92; ACC102; ACC05 and optional I/O — shared +24 V rail | — | Edit | ||
| Salt Spray Premium120 - 1300 | 25 | Open-canopy command on PLC / emergency-stop side | NO | Passes through S4; the solenoid-side conductor is wire 236. | Edit | ||
| Salt Spray Premium120 - 1300 | 26 | Dry air solenoid Y3 command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 27 | Close-canopy command on PLC / emergency-stop side | NO | Passes through S4; the solenoid-side conductor is wire 237. | Edit | ||
| Salt Spray Premium120 - 1300 | 28 | Canopy closed proximity-switch input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 31 | Pump M1 black motor lead between F2V1 and PERC010 | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 32 | Pump M2 black motor lead between F2V2 and PERC010 | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 34 | Buzzer command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 35 | Air-saturator heater E2 load conductor to relay K1 | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | Edit | ||
| Salt Spray Premium120 - 1300 | 36 | Air-saturator heater relay K1 control | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 37 | Chamber / cabinet heater relay K2 control | NO | PLC page labels this output CHAMBER HEATER. | Edit | ||
| Salt Spray Premium120 - 1300 | 38 | Immersion-heater relay K10 control | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 39 | Cabinet heater E4/A load conductor to relay K2 | NO | Other model-specific cabinet-heater branches use wires 107 and 108. | Edit | ||
| Salt Spray Premium120 - 1300 | 4 | Protected AC live distribution from MCB2 to the 24 V PSU and accessory branch | YES — SHAREDInternal Illumination option — shared protected live feed | Feeds PLCC303 L and the optional internal-illumination MCB3 branch. | Edit | ||
| Salt Spray Premium120 - 1300 | 44 | Internal-illumination switched lamp / relay-contact conductor | YESInternal Illumination (OPTION) | Shown only inside the INTERNAL ILLUMINATION (OPTION) box. | Edit | ||
| Salt Spray Premium120 - 1300 | 45 | Internal-illumination relay K17 command | YESInternal Illumination (OPTION) | — | Edit | ||
| Salt Spray Premium120 - 1300 | 470 | Guardian Angel fatal-error warning | YESACC05 — Guardian Angel (OPTION) | — | Edit | ||
| Salt Spray Premium120 - 1300 | 471 | Guardian Angel non-fatal error warning | YESACC05 — Guardian Angel (OPTION) | — | Edit | ||
| Salt Spray Premium120 - 1300 | 472 | Guardian Angel system-healthy output | YESACC05 — Guardian Angel (OPTION) | — | Edit | ||
| Salt Spray Premium120 - 1300 | 5 | Pump M1 red motor lead between F2V1 and PERC010 | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 54 | Immersion heater E7/A load conductor to relay K10 | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier; used on models B, C, J and K. | Edit | ||
| Salt Spray Premium120 - 1300 | 58 | Air-curtain solenoid Y33 command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 59 | Base-fill solenoid group command | NO | Page 3 shows wire 59 driving the base-fill valve group. | Edit | ||
| Salt Spray Premium120 - 1300 | 6 | HUMA030 RH1 humidity-probe analogue signal (white lead) | YESHUMA030 RH1 humidity probe (OPTIONAL) | HUMA030 RH1 is explicitly shown inside an OPTIONAL box. | Edit | ||
| Salt Spray Premium120 - 1300 | 60 | Optional-accessory output; page 6 says AIR SATURATOR MANUAL FILL, page 7 shows HIGH WATER LEVEL lamp | YES — OPTIONAL I/OOptional accessories card / High Water Level circuit | The drawing gives two different function labels for wire 60; both are retained here rather than reconciled. | Edit | ||
| Salt Spray Premium120 - 1300 | 63 | O/T 8 over-temperature input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 64 | O/T 7 over-temperature input | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 65 | O/T 12 over-temperature input | NO | PLC page labels wire 65 O/T 12; page 4 shows it as a branch from the additional O/T chain. | Edit | ||
| Salt Spray Premium120 - 1300 | 7 | Purge solenoid Y5 command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 76 | Pump 1 pulse / speed command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 77 | Pump 2 pulse / speed command | NO | — | Edit | ||
| Salt Spray Premium120 - 1300 | 8 | 0 V DC control rail | YES — SHAREDHUMA030 RH1; ACC20; ACC92; ACC102; ACC46; ACC05; Internal Illumination — shared 0 V rail | — | Edit | ||
| Salt Spray Premium120 - 1300 | 83 | SO2 fill solenoid Y26 command | YESACC46 — SO2 Fill | — | Edit | ||
| Salt Spray Premium120 - 1300 | 87 | Mains live interconnect in the filter / RCBO path | NO | Its position changes with the integral vs non-integral filter arrangement. | Edit | ||
| Salt Spray Premium120 - 1300 | 88 | Filtered neutral interconnect from ELEC514 toward Q1 | NO | Shown in the mains-filter-integral-to-connector arrangement. | Edit | ||
| Salt Spray Premium120 - 1300 | 9 | PNEC069 S5 air-pressure sensor analogue signal (black lead) | NO | Brown/blue are supply/return; wire 9 is the signal into PLCC017. | Edit | ||
| Salt Spray Premium120 - 1300 | 96 | Air-saturator heater-inhibit optical sensor input | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 1 | Cabinet mains live distribution feed to heater circuits | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | Edit | ||
| Salt Spray Standard120 - 1300 | 10 | Over-temperature stat input (O/T chain) | NO | O/T 1 and O/T 2 are wired in series on page 4. | Edit | ||
| Salt Spray Standard120 - 1300 | 1004 | Air saturator heater mains feed between MCB8 and relay K1 | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 11 | Series link between O/T 1 and O/T 2 thermostats | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 123 | ACC20 full switch input | YESACC20 — Waste Water Trough & Pump System | — | Edit | ||
| Salt Spray Standard120 - 1300 | 14 | Moist air solenoid Y4 | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 144 | Internal illumination relay switched-contact bus | YESInternal Illumination (OPTION) | — | Edit | ||
| Salt Spray Standard120 - 1300 | 147 | Salt tank low water alarm input | YES — MODEL/OPTIONSalt Tank Low Water Alarm option; standard on E/F/G | Drawing notes this option is fitted as standard to models E, F and G. | Edit | ||
| Salt Spray Standard120 - 1300 | 15 | Cabinet mains live conductor in the Q1 / RC1 power-management path | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | Edit | ||
| Salt Spray Standard120 - 1300 | 16 | Cabinet mains live conductor from RC1 toward ELEC516.1 | NO | Shown in the non-integral mains-filter arrangement. | Edit | ||
| Salt Spray Standard120 - 1300 | 18 | Emergency stop input | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 19 | Canopy open switch input | NO | Page 4 shows the associated pneumatic sensor switch circuit. | Edit | ||
| Salt Spray Standard120 - 1300 | 190 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-8 of this issue. | Edit | ||
| Salt Spray Standard120 - 1300 | 2 | Cabinet mains neutral / common return | YES — SHAREDChart Recorder / accessory circuits — shared mains return | Also feeds optional chart-recorder/accessory circuits. | Edit | ||
| Salt Spray Standard120 - 1300 | 20 | Air saturator auto-fill solenoid Y1 | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 200 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-8 of this issue. | Edit | ||
| Salt Spray Standard120 - 1300 | 21 | Air saturator FULL optical sensor | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 22 | Air saturator LOW optical sensor | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 23 | Vent solenoid Y2 | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 236 | Emergency-stop / canopy solenoid interlock conductor | NO | One of the paired interlock conductors shown between S4 and the canopy-solenoid circuit. | Edit | ||
| Salt Spray Standard120 - 1300 | 237 | Emergency-stop / canopy solenoid interlock conductor | NO | One of the paired interlock conductors shown between S4 and the canopy-solenoid circuit. | Edit | ||
| Salt Spray Standard120 - 1300 | 24 | +24 V DC control rail | YES — SHAREDMultiple optional accessories — shared DC control rail | — | Edit | ||
| Salt Spray Standard120 - 1300 | 25 | Open canopy command / solenoid Y10 | NO | Canopy interlock wiring also passes through the emergency-stop circuit. | Edit | ||
| Salt Spray Standard120 - 1300 | 26 | Dry air solenoid Y3 | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 27 | Close canopy command / solenoid Y11 | NO | Canopy interlock wiring also passes through the emergency-stop circuit. | Edit | ||
| Salt Spray Standard120 - 1300 | 28 | Canopy closed proximity switch input | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 31 | Pump motor black lead (M1 / M6 via PERC010) | YES — SHAREDPump Motor 2 / second pump shares this motor-lead identifier | Used on the standard pump and the optional/model-specific second pump. | Edit | ||
| Salt Spray Standard120 - 1300 | 34 | Buzzer | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 35 | Air saturator heater E2 load conductor | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | Edit | ||
| Salt Spray Standard120 - 1300 | 36 | Air saturator heater control | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 37 | Chamber / cabinet heater relay K2 control | NO | PLC page names the output 'Chamber Heater'. | Edit | ||
| Salt Spray Standard120 - 1300 | 39 | Cabinet heater load conductor | NO | Feeds E4/A, E4/B and E4/C as applicable by model. | Edit | ||
| Salt Spray Standard120 - 1300 | 4 | AC live accessory / chart-recorder feed | YES — SHAREDInternal Illumination; Chart Recorder options | Used by the internal-illumination and chart-recorder branches. | Edit | ||
| Salt Spray Standard120 - 1300 | 400 | Chart recorder / independent PT100 option signal link via 10 Ω resistor | YESChart Recorder / Independent PT100 option | — | Edit | ||
| Salt Spray Standard120 - 1300 | 44 | Internal illumination switched lamp feed | YESInternal Illumination (OPTION) | — | Edit | ||
| Salt Spray Standard120 - 1300 | 441 | ACC92 option output to Y50 / V3 | YESACC92 option | The drawing identifies the output as ACC92 but does not further name its function. | Edit | ||
| Salt Spray Standard120 - 1300 | 45 | Internal illumination relay command | YESInternal Illumination (OPTION) | — | Edit | ||
| Salt Spray Standard120 - 1300 | 5 | Pump motor red lead (M1 / M6 via PERC010) | YES — SHAREDPump Motor 2 / second pump shares this motor-lead identifier | Used on the standard pump and the optional/model-specific second pump. | Edit | ||
| Salt Spray Standard120 - 1300 | 60 | High water warning lamp | YESHigh Water Lamp (OPTION) | — | Edit | ||
| Salt Spray Standard120 - 1300 | 7 | Purge solenoid Y5 | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 76 | Pump motor 1 command | NO | — | Edit | ||
| Salt Spray Standard120 - 1300 | 77 | Pump motor 2 command | YESPump Motor 2 / second pump (Model D only) | Page 6 explicitly labels Pump Motor 2 as optional; page 3 shows Model D only. | Edit | ||
| Salt Spray Standard120 - 1300 | 8 | 0 V DC control rail | YES — SHAREDMultiple optional accessories — shared DC control rail | — | Edit | ||
| Salt Spray Standard120 - 1300 | 87 | Protected mains live interconnect in the mains filter / RC1 path | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | Edit | ||
| Salt Spray Standard120 - 1300 | 88 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-8 of this issue. | Edit | ||
| Salt Spray Standard120 - 1300 | 96 | Air saturator inhibit input | NO | — | Edit |