Review candidates, not confirmed electrical faults. Models, options and circuit instances may legitimately reuse a number. Wording differences do not prove a wrong function; the extraction is not a complete netlist.

74 entries need review. Export CSV · Drawing links

ATCU · Wire 8

Current function: Stage 1 compressor phase conductor | 0 V DC common

Open wire editor

CFX · Wire 10

Current function: Over-temperature thermostat O/T1 | O/T1 input

Open wire editor

CFX · Wire 1004

Current function: Heater/blower auxiliary supply; also air-drying blower supply | Air drying blower supply

Open wire editor

CFX · Wire 101

Current function: Z1 output / chamber power distribution | Shared power/supply conductor used by ACC30 / ACC102 circuits

Open wire editor

CFX · Wire 11

Current function: Over-temperature thermostat O/T2 | O/T2 input

Open wire editor

CFX · Wire 113

Current function: Blower over-temperature thermostat O/T6 circuit | ATCU compressor stage 2 phase conductor

Open wire editor

CFX · Wire 115

Current function: Salt Spray / Water Fog pump 1-2 motor or drive interconnect | ATCU heater contactor input phase

Open wire editor

CFX · Wire 116

Current function: Salt Spray / Water Fog pump 1-2 motor or drive interconnect | ATCU heater contactor input phase

Open wire editor

CFX · Wire 117

Current function: Sulphur Dioxide Supply Valve | Sulphur dioxide supply valve

Open wire editor

CFX · Wire 123

Current function: ACC20 waste-water trough full switch | ACC20 full switch | Common feed used by user programmable digital outputs

Open wire editor

CFX · Wire 125

Current function: ACC92 scrubber flow signal | Scrubber flow meter signal

Open wire editor

CFX · Wire 1265

Current function: ACC29 Butterfly Valve | Refrigeration & humidity control butterfly valve

Open wire editor

CFX · Wire 134

Current function: Spot Cooler | Spot cooler relay command

Open wire editor

CFX · Wire 137

Current function: Additional Side Heater Mats | Additional side heater mats relay command

Open wire editor

CFX · Wire 14

Current function: Moist air valve | Moist air

Open wire editor

CFX · Wire 146

Current function: ACC102 salt solution consumption sensor signal | Salt solution consumption sensor signal

Open wire editor

CFX · Wire 147

Current function: Salt tank low-water alarm | Salt tank low water alarm

Open wire editor

CFX · Wire 164

Current function: ATCU OK | ATCU plant healthy

Open wire editor

CFX · Wire 170

Current function: Blower ball-valve position | Blower ball valve position feedback

Open wire editor

CFX · Wire 173

Current function: Low water | Water low input

Open wire editor

CFX · Wire 18

Current function: Emergency stop feedback | Emergency stop input | ATCU heater SSR2 output

Open wire editor

CFX · Wire 19

Current function: Canopy opened | Canopy opened input | ATCU heater SSR3 output

Open wire editor

CFX · Wire 198

Current function: Heater over-temperature count / O/T10 chain | Heater over-temperature count input

Open wire editor

CFX · Wire 2

Current function: Incoming mains cable core for L2; also reused as AC neutral in internal circuits | Air drying blower neutral | Shared power/supply conductor used by ACC30 / ACC102 circuits

Open wire editor

CFX · Wire 20

Current function: Auto fill valve | Auto fill

Open wire editor

CFX · Wire 21

Current function: Air saturator full | Air saturator full input

Open wire editor

CFX · Wire 210

Current function: Heat | ATCU HEAT input

Open wire editor

CFX · Wire 22

Current function: Air saturator low | Air saturator low input

Open wire editor

CFX · Wire 24

Current function: +24 V DC control supply | +24 V supply to optional output cards | Supply to PT100 / analogue cards including ACC34 option | Shared supply/return used by page 15 optional accessories | Shared supply/return to ACC42 / ACC46 / ACC29 accessories | Shared supply/return to ACC92 / ACC31 / ACC66 / ACC59 accessories | Shared power/supply conductor used by ACC30 / ACC102 circuits | Shared supply/return for page 19 optional accessories | Shared supply/return for ACC36 remote transmission and optional remote controls

Open wire editor

CFX · Wire 250

Current function: Air distribution bar | Air bar

Open wire editor

CFX · Wire 252

Current function: Salt Spray Motor Run | Salt spray vertically-down motor run relay command

Open wire editor

CFX · Wire 26

Current function: Dry air valve | Dry air

Open wire editor

CFX · Wire 265

Current function: Run | ATCU RUN input

Open wire editor

CFX · Wire 28

Current function: Canopy closed | Optional pneumatic sensor switch S23 connection into canopy-closed input | Canopy closed input

Open wire editor

CFX · Wire 286

Current function: Humidify | ATCU HUMIDITY input

Open wire editor

CFX · Wire 289

Current function: P_Fill | Psychometric water fill / P_Fill

Open wire editor

CFX · Wire 33

Current function: Blower Ball Valve(s) c/w Position Switch(es) | Blower ball valve drive

Open wire editor

CFX · Wire 340

Current function: Door seal command after emergency-stop interlock | Door seal

Open wire editor

CFX · Wire 341

Current function: Door unseal command after emergency-stop interlock | Door unseal

Open wire editor

CFX · Wire 342

Current function: Door sealed feedback | Door sealed

Open wire editor

CFX · Wire 36

Current function: Air saturator heater relay command | Air saturator heater

Open wire editor

CFX · Wire 37

Current function: Chamber heater relay command | Chamber heater

Open wire editor

CFX · Wire 38

Current function: Immersion heater relay command | Immersion heater

Open wire editor

CFX · Wire 441

Current function: Salt Scrubber Valve | Exhaust salt scrubber valve

Open wire editor

CFX · Wire 45

Current function: Interior illumination relay command | Interior Illumination

Open wire editor

CFX · Wire 450

Current function: Purge Valve for Salt Spray | Salt spray purge valve

Open wire editor

CFX · Wire 463

Current function: Pressure Release Valve for Salt Spray | Salt spray pressure release valve

Open wire editor

CFX · Wire 470

Current function: GA - Fatal Error Warning | Guardian Angel fatal

Open wire editor

CFX · Wire 471

Current function: GA - Non-Fatal Error Warning | Guardian Angel non-fatal

Open wire editor

CFX · Wire 472

Current function: GA - System Healthy | Guardian Angel healthy

Open wire editor

CFX · Wire 48

Current function: Blower heater control / optional output | Blower Heater

Open wire editor

CFX · Wire 480

Current function: Spraybar parked | Spraybar parked sensor signal

Open wire editor

CFX · Wire 50

Current function: Wash Down Valve | Wall wash down valve

Open wire editor

CFX · Wire 500

Current function: Oscillating Spray Bar Motor Engage | Oscillating spray bar motor engage

Open wire editor

CFX · Wire 504

Current function: Additional Salt Spray / Water Fog pump motor/F2V interconnect | Corroflex Pump Output 3

Open wire editor

CFX · Wire 519

Current function: Air Saturator 2 / Water Fog / Salt Spray changeover solenoid circuit | Water Fog N/C solenoid / Salt Spray N/O solenoid

Open wire editor

CFX · Wire 560

Current function: De-Humidify | ATCU DEHUMID input

Open wire editor

CFX · Wire 58

Current function: Salt Spray Air Valve | Salt Spray Air Solenoid

Open wire editor

CFX · Wire 59

Current function: Base fill valve | Base fill

Open wire editor

CFX · Wire 598

Current function: ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M19

Open wire editor

CFX · Wire 60

Current function: High Water Warning Lamp | High water lamp

Open wire editor

CFX · Wire 601

Current function: ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M20

Open wire editor

CFX · Wire 604

Current function: ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M21

Open wire editor

CFX · Wire 608

Current function: ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M22

Open wire editor

CFX · Wire 63

Current function: Over-temperature thermostat O/T8 | O/T8 input

Open wire editor

CFX · Wire 64

Current function: Over-temperature thermostat O/T7 | O/T7 input

Open wire editor

CFX · Wire 68

Current function: Cool | ATCU COOL input

Open wire editor

CFX · Wire 8

Current function: 0 V DC common | 0 V return for optional output cards | Supply to PT100 / analogue cards including ACC34 option | Shared supply/return used by page 15 optional accessories | Shared supply/return to ACC42 / ACC46 / ACC29 accessories | Shared supply/return to ACC92 / ACC31 / ACC66 / ACC59 accessories | Shared power/supply conductor used by ACC30 / ACC102 circuits | Shared supply/return for page 19 optional accessories | Shared supply/return for ACC36 remote transmission and optional remote controls

Open wire editor

CFX · Wire 85

Current function: Base drain valve | Base drain

Open wire editor

CFX · Wire 91

Current function: Low air pressure | Low-air input

Open wire editor

CFX · Wire 96

Current function: Air saturator heater inhibit | Air saturator inhibit input

Open wire editor

CYCLIC · Wire 2

Current function: Incoming main-supply cable/core marking on L2 | AC neutral/common return used throughout heater and option circuits

Open wire editor

CYCLIC · Wire 250

Current function: K16 T1 to immersion heater E6/A | Air bar / ACC46 purge air bar output

Open wire editor

CYCLIC · Wire 4

Current function: Incoming main-supply cable/core marking on N | 24 V power-supply AC live feed after MCB6; also accessory live feed

Open wire editor