CP Chamber Parts

machine

CFX

ASCOTT Corroflex

Edit

Details

Status
Active
Description
Parent

Images

Bill of materials

Total £0.00
PartDescriptionReferenceQtyUnitTotal
No BOM lines.

Wire numbers

328 wires
WireName / definitionOptional extraNotesFromTo
0LACC29 ATCU local neutralYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
1Incoming mains cable core for L1NO
Edit
10Over-temperature thermostat O/T1 | O/T1 inputNO
Edit
100Z1 output / chamber power distributionNO
Edit
1000Heater/blower mains distribution conductorNO
Edit
1001Heater/blower mains distribution conductorNO
Edit
1002Heater/blower mains distribution conductorNO
Edit
1004Heater/blower auxiliary supply; also air-drying blower supply | Air drying blower supplyNO
Edit
1005Air saturator heater supplyNO
Edit
101Z1 output / chamber power distribution | Shared power/supply conductor used by ACC30 / ACC102 circuitsYES — SHAREDACC30 / ACC102
Edit
102Z1 output / chamber power distributionNO
Edit
105ATCU air circulation fan phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
106ATCU air circulation fan phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
107ATCU air circulation fan phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
108ATCU compressor stage 1 phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
109ATCU compressor stage 1 phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
11Over-temperature thermostat O/T2 | O/T2 inputNO
Edit
110ATCU compressor stage 1 phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
111ATCU compressor stage 2 phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
112ATCU compressor stage 2 phase conductorYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
113Blower over-temperature thermostat O/T6 circuit | ATCU compressor stage 2 phase conductorYES — SHAREDACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
1133User Programmable Digital Output 2YESUser programmable output 2, User Programmable Digital Output 2Named on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
114ATCU heater contactor input phaseYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
115Salt Spray / Water Fog pump 1-2 motor or drive interconnect | ATCU heater contactor input phaseYES — SHAREDACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
116Salt Spray / Water Fog pump 1-2 motor or drive interconnect | ATCU heater contactor input phaseYES — SHAREDACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
117Sulphur Dioxide Supply Valve | Sulphur dioxide supply valveYESACC46 Sulphur dioxide dosingNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
1180User Programmable Digital Output 2 relay/contact conductorYESUser Programmable Digital Output 2
Edit
1181User Programmable Digital Output 2 relay/contact conductorYESUser Programmable Digital Output 2
Edit
1182User Programmable Digital Output 2 relay/contact conductorYESUser Programmable Digital Output 2
Edit
1183User Programmable Digital Output 2 relay/contact conductorYESUser Programmable Digital Output 2
Edit
1189Phase input to Z1NO
Edit
121Air Saturator 2 fullYESSecond air saturator optionUsed when the second air saturator / door-seal control is fitted.
Edit
122ATCU condenser fan branch feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
123ACC20 waste-water trough full switch | ACC20 full switch | Common feed used by user programmable digital outputsYES — SHAREDACC20 Waste water trough & pump, User programmable digital outputs
Edit
1233User Programmable Digital Output 4YESUser Programmable Digital Output 4, Remote controls / Two-button canopy / user outputs
Edit
124ATCU de-superheater fan branch feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
125ACC92 scrubber flow signal | Scrubber flow meter signalYESACC92 Exhaust salt scrubber
Edit
126ATCU crankcase-heater branch feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
1265ACC29 Butterfly Valve | Refrigeration & humidity control butterfly valveYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
127ATCU crankcase heater stage 1 feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
128ATCU crankcase heater stage 2 feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
132Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
133User Programmable Digital Output 1YESUser programmable output 1, User Programmable Digital Output 1Named on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
134Spot Cooler | Spot cooler relay commandYESACC90 Spot coolerNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
135Air Saturator 2 Water/Fog changeover solenoidYESSecond air saturator option
Edit
136Multi Solution changeover solenoidYESACC86 Multi Solution
Edit
137Additional Side Heater Mats | Additional side heater mats relay commandYESAdditional side heater matsNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
139Additional side heater mat switched conductorYESAdditional side heater mats
Edit
14Moist air valve | Moist airNO
Edit
144Interior illumination switched mains feed after MCB7NO
Edit
146ACC102 salt solution consumption sensor signal | Salt solution consumption sensor signalYESACC102, ACC102 Salt solution consumption sensor
Edit
147Salt tank low-water alarm | Salt tank low water alarmYESACC59 salt tank alarm option
Edit
148Second blower ball valve position/contact conductorYESACC39 / ACC47 Blower ball valve
Edit
150ATCU stage 1 COOL solenoid switched feedYESACC29 Refrigeration & humidity control
Edit
151ATCU stage 1 BYPASS solenoid switched feedYESACC29 Refrigeration & humidity control
Edit
152ATCU stage 2 COOL solenoid switched feedYESACC29 Refrigeration & humidity control
Edit
153ATCU stage 2 BYPASS solenoid switched feedYESACC29 Refrigeration & humidity control
Edit
154ATCU DEHUMID solenoid switched feedYESACC29 Refrigeration & humidity control
Edit
1580User Programmable Digital Output 4 relay/contact conductorYESUser Programmable Digital Output 4
Edit
1581User Programmable Digital Output 4 relay/contact conductorYESUser Programmable Digital Output 4
Edit
1582User Programmable Digital Output 4 relay/contact conductorYESUser Programmable Digital Output 4
Edit
1583User Programmable Digital Output 4 relay/contact conductorYESUser Programmable Digital Output 4
Edit
164ATCU OK | ATCU plant healthyYES — SHAREDACC29 Refrigeration & humidity control
Edit
17ATCU heater SSR1 outputYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
170Blower ball-valve position | Blower ball valve position feedbackYESACC39 / ACC47 Blower ball valve
Edit
173Low water | Water low inputNO
Edit
177Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
18Emergency stop feedback | Emergency stop input | ATCU heater SSR2 outputYES — SHAREDACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
180User Programmable Digital Output 1 relay/contact conductorYESUser Programmable Digital Output 1
Edit
181User Programmable Digital Output 1 relay/contact conductorYESUser Programmable Digital Output 1
Edit
182User Programmable Digital Output 1 relay/contact conductorYESUser Programmable Digital Output 1
Edit
183User Programmable Digital Output 1 relay/contact conductorYESUser Programmable Digital Output 1
Edit
185Psychometric drainsYESACC29 Refrigeration & humidity control
Edit
187Phase input to Z1NO
Edit
188Phase input to Z1NO
Edit
1889Phase feed from X1 to MCB30 / MCB3NO
Edit
189Phase feed after MCB30 to optional ATCU power pagesNO
Edit
1890ACC29 ATCU phase after MCB21YESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
19Canopy opened | Canopy opened input | ATCU heater SSR3 outputYES — SHAREDACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
191Spot cooler mains feed after MCB15YESACC90 Spot cooler
Edit
196Air Saturator 2 heater inhibitYESSecond air saturator optionUsed when the second air saturator / door-seal control is fitted.
Edit
198Heater over-temperature count / O/T10 chain | Heater over-temperature count inputNO
Edit
1981O/T11 thermostat intermediate conductorNO
Edit
1LACC29 ATCU local phase 1YESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
2Incoming mains cable core for L2; also reused as AC neutral in internal circuits | Air drying blower neutral | Shared power/supply conductor used by ACC30 / ACC102 circuitsYES — SHAREDACC30 / ACC102
Edit
20Auto fill valve | Auto fillNO
Edit
21Air saturator full | Air saturator full inputNO
Edit
210Heat | ATCU HEAT inputYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
213Remote PAUSEYESRemote controls / Two-button canopy / user outputs
Edit
214Remote UNPAUSEYESRemote controls / Two-button canopy / user outputs
Edit
215Remote STARTYESRemote controls / Two-button canopy / user outputs
Edit
216Remote STOPYESRemote controls / Two-button canopy / user outputs
Edit
217Two Button Canopy Option inputYESRemote controls / Two-button canopy / user outputs
Edit
22Air saturator low | Air saturator low inputNO
Edit
222Air Saturator 2 lowYESSecond air saturator optionUsed when the second air saturator / door-seal control is fitted.
Edit
233User Programmable Digital Output 3YESUser Programmable Digital Output 3, Remote controls / Two-button canopy / user outputs
Edit
236Door/open control feed before E-stop interlockNO
Edit
237Door/close control feed before E-stop interlockNO
Edit
238Door seal control feed before E-stop interlockNO
Edit
239Door unseal control feed before E-stop interlockNO
Edit
24+24 V DC control supply | +24 V supply to optional output cards | Supply to PT100 / analogue cards including ACC34 option | Shared supply/return used by page 15 optional accessories | Shared supply/return to ACC42 / ACC46 / ACC29 accessories | Shared supply/return to ACC92 / ACC31 / ACC66 / ACC59 accessories | Shared power/supply conductor used by ACC30 / ACC102 circuits | Shared supply/return for page 19 optional accessories | Shared supply/return for ACC36 remote transmission and optional remote controlsYES — SHAREDOptional output cards, ACC34 optional PT100, ACC20 / ACC90 / additional pump options, ACC42 / ACC46 / ACC29, ACC92 / ACC31 / ACC66 / ACC59, ACC30 / ACC102, ACC39 / ACC47 / ACC05 / user outputs, ACC36 / Remote controls / Two-button canopyDefined by the wire-identification table on page 1. ACC34 sensor leads are colour/terminal identified rather than assigned separate numeric wire IDs.
Edit
24LACC29 ATCU +24 V DCYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
25Open canopyNO
Edit
250Air distribution bar | Air barNO
Edit
252Salt Spray Motor Run | Salt spray vertically-down motor run relay commandYESACC30 Salt spray vertically downNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
26Dry air valve | Dry airNO
Edit
265Run | ATCU RUN inputYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
27Close canopyNO
Edit
28Canopy closed | Optional pneumatic sensor switch S23 connection into canopy-closed input | Canopy closed inputYES — SHAREDOptional pneumatic sensor switch S23The drawing labels S23 'PNEUMATIC SENSOR SWITCH OPTIONAL'.
Edit
286Humidify | ATCU HUMIDITY inputYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
289P_Fill | Psychometric water fill / P_FillYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
2LACC29 ATCU local phase 2YESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
3Incoming mains cable core for L3NO
Edit
31Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
311Air curtainNO
Edit
317ATCU heater 1 feed after protectionYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
318ATCU heater 2 feed after protectionYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
319ATCU heater 3 feed after protectionYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
32Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
323ATCU condenser fan switched feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
325ATCU de-superheater fan switched feedYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
33Blower Ball Valve(s) c/w Position Switch(es) | Blower ball valve driveYESACC39 / ACC47 Blower ball valveNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
34BuzzerNO
Edit
340Door seal command after emergency-stop interlock | Door sealNO
Edit
341Door unseal command after emergency-stop interlock | Door unsealNO
Edit
342Door sealed feedback | Door sealedNOUsed when the second air saturator / door-seal control is fitted.
Edit
343Canopy unsealedNOUsed when the second air saturator / door-seal control is fitted.
Edit
344ATCU compressor stage 1 contactorYESACC29 Refrigeration & humidity control
Edit
345ATCU compressor stage 2 contactorYESACC29 Refrigeration & humidity control
Edit
35-1Air saturator 1 heater circuitNO
Edit
35-2Air saturator 2 heater circuitNO
Edit
350ATCU stage 1 cool solenoid relayYESACC29 Refrigeration & humidity control
Edit
352Salt spray vertically-down motor switched conductorYESACC30 Salt spray vertically down
Edit
353Salt spray vertically-down motor relay output conductorYESACC30 Salt spray vertically down
Edit
354ATCU dehumidification solenoid relayYESACC29 Refrigeration & humidity control
Edit
36Air saturator heater relay command | Air saturator heaterNO
Edit
37Chamber heater relay command | Chamber heaterNO
Edit
370Inverter enableNO
Edit
374ATCU air temperature limit (60C)YESACC29 Refrigeration & humidity control
Edit
375ATCU PLC input I4 - function not namedYESACC29 Refrigeration & humidity control
Edit
376ATCU PLC input I5 - function not namedYESACC29 Refrigeration & humidity control
Edit
377ATCU PLC input I6 - function not namedYESACC29 Refrigeration & humidity control
Edit
38Immersion heater relay command | Immersion heaterNO
Edit
380ATCU recirculation fan overloadYESACC29 Refrigeration & humidity control
Edit
381ATCU stage 1 compressor overloadYESACC29 Refrigeration & humidity control
Edit
385ATCU PLC input I14 - function not namedYESACC29 Refrigeration & humidity control
Edit
387ATCU PLC input I16 - function not namedYESACC29 Refrigeration & humidity control
Edit
39-1Heater bank E1 switched conductorNO
Edit
39-2Heater bank E2 switched conductorNO
Edit
39-3Heater bank E3 switched conductorNO
Edit
392ATCU heater SSR controlYESACC29 Refrigeration & humidity control
Edit
393ATCU Y36 solenoid outputYESACC29 Refrigeration & humidity control
Edit
3LACC29 ATCU local phase 3YESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
4Incoming mains cable core for N; also reused as AC live/control feed after MCB6/MCB7NO
Edit
4018-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
402Multi Solution Spray Motor M17YES — OPTIONAL I/OACC86 Multi SolutionNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
4038-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
404Multi Solution Spray Motor M18YES — OPTIONAL I/OACC86 Multi SolutionNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
405Salt Spray 3 / Water Fog 3YES — OPTIONAL I/OAdditional spray pump outputNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
4068-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
4078-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
41ATCU PLC relay output Q2 - function not namedYESACC29 Refrigeration & humidity control
Edit
410Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
412Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
413ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
414ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
415Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
416ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
417Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
418ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
419Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
42ATCU PLC relay output Q3 - function not namedYESACC29 Refrigeration & humidity control
Edit
422Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
424Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
425Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
426ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
427ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
428ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
429ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
43ATCU air circulation fan contactorYESACC29 Refrigeration & humidity control
Edit
430CompYES — OPTIONAL I/OACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
431Salt Spray / Water Fog pump 3-4 motor interconnectYESACC29-dependent additional spray pumpsShown on circuits marked 'Fit With ACC29'.
Edit
432Salt Spray / Water Fog pump 3-4 motor interconnectYESACC29-dependent additional spray pumpsShown on circuits marked 'Fit With ACC29'.
Edit
433Salt Spray / Water Fog pump 3-4 motor interconnectYESACC29-dependent additional spray pumpsShown on circuits marked 'Fit With ACC29'.
Edit
434Salt Spray / Water Fog pump 3-4 motor interconnectYESACC29-dependent additional spray pumpsShown on circuits marked 'Fit With ACC29'.
Edit
435Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
436Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
437Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
438Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
439ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
44Interior illumination lamp circuit conductorNO
Edit
440ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
441Salt Scrubber Valve | Exhaust salt scrubber valveYESACC92 Exhaust salt scrubberNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
442ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
443ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
444ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
445ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
446ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
45Interior illumination relay command | Interior IlluminationYES — OPTIONAL I/OACC26 / Interior illuminationNamed 'Interior Illumination' on the optional output card. Named on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
450Purge Valve for Salt Spray | Salt spray purge valveYESACC30 Salt spray vertically downNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
46ATCU heater contactor command before OT2YESACC29 Refrigeration & humidity control
Edit
463Pressure Release Valve for Salt Spray | Salt spray pressure release valveYESACC30 Salt spray vertically downNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
470GA - Fatal Error Warning | Guardian Angel fatalYESACC05 Guardian AngelNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
471GA - Non-Fatal Error Warning | Guardian Angel non-fatalYESACC05 Guardian AngelNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
472GA - System Healthy | Guardian Angel healthyYESACC05 Guardian AngelNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
474Salt Spray 4 / Water Fog 4YES — OPTIONAL I/OAdditional spray pump outputNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
4758-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
48Blower heater control / optional output | Blower HeaterYES — OPTIONAL I/OBlower heater optional outputNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
480Spraybar parked | Spraybar parked sensor signalYESACC31 Oscillating spray bar, ACC31/1 or ACC31/2
Edit
4LACC29 ATCU PLC/control AC liveYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
50Wash Down Valve | Wall wash down valveYESACC42 Wall wash downNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
500Oscillating Spray Bar Motor Engage | Oscillating spray bar motor engageYESACC31 Oscillating spray barNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
502Oscillating spray bar motor conductorYESACC31 Oscillating spray bar
Edit
504Additional Salt Spray / Water Fog pump motor/F2V interconnect | Corroflex Pump Output 3YESACC29-dependent additional spray pumps, Additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
51ATCU stage 1 bypass solenoid relayYESACC29 Refrigeration & humidity control
Edit
519Air Saturator 2 / Water Fog / Salt Spray changeover solenoid circuit | Water Fog N/C solenoid / Salt Spray N/O solenoidNO
Edit
52ATCU stage 2 cool solenoid relayYESACC29 Refrigeration & humidity control
Edit
53ATCU stage 2 bypass solenoid relayYESACC29 Refrigeration & humidity control
Edit
537Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
538Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
539Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
54-1Immersion heater switched conductorNO
Edit
54-2Immersion heater switched conductorNO
Edit
54-3Immersion heater switched conductorNO
Edit
540Additional Salt Spray / Water Fog pump motor/F2V interconnectYESACC29-dependent additional spray pumpsShown in the additional-pumps circuits with ACC29 annotations.
Edit
541ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
55ATCU PLC relay output Q13 - function not namedYESACC29 Refrigeration & humidity control
Edit
560De-Humidify | ATCU DEHUMID inputYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
5638-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
5648-channel analogue output to optional pump/F2V driveYES — OPTIONAL I/OACC29 / ACC86 additional pump drivesChannel function depends on the fitted pump/option.
Edit
57ATCU heater contactor command after OT2YESACC29 Refrigeration & humidity control
Edit
58Salt Spray Air Valve | Salt Spray Air SolenoidYESAdditional spray pumpsNamed on the sheet titled 'OPTIONAL OUTPUTS'. Optional if additional pumps are fitted.
Edit
580User Programmable Digital Output 3 relay/contact conductorYESUser Programmable Digital Output 3
Edit
581User Programmable Digital Output 3 relay/contact conductorYESUser Programmable Digital Output 3
Edit
582User Programmable Digital Output 3 relay/contact conductorYESUser Programmable Digital Output 3
Edit
583User Programmable Digital Output 3 relay/contact conductorYESUser Programmable Digital Output 3
Edit
59Base fill valve | Base fillNO
Edit
598ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M19YESACC86 Multi Solution
Edit
60High Water Warning Lamp | High water lampYESACC66 High water lampNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
601ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M20YESACC86 Multi Solution
Edit
604ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M21YESACC86 Multi Solution
Edit
608ACC86 Multi Solution pump / F2V / motor interconnect | Multi Solution Spray Motor M22YESACC86 Multi Solution
Edit
612ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
614ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
615ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
616ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
617ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
618ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
619ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
620ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
63Over-temperature thermostat O/T8 | O/T8 inputNO
Edit
637ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
638ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
639ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
64Over-temperature thermostat O/T7 | O/T7 inputNO
Edit
640ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
641ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
642ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
643ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
644ACC86 Multi Solution pump / F2V / motor interconnectYESACC86 Multi Solution
Edit
650ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
651ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
652ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
653ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
654ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
655ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
656ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
657ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
658ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
659ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
660ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
661ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
662ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
663ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
668ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
669ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
670ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
671ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
672ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
673ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
674ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
675ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
676ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
677ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
678ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
679ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
68Cool | ATCU COOL inputYESACC29 Refrigeration & humidity controlNamed on the sheet titled 'OPTIONAL OUTPUTS'.
Edit
680ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
681ECC1 additional atomiser pump / F2V / motor interconnectYESACC25 ECC1 additional atomisers
Edit
686ECC1 Pump 1YESACC25 ECC1 additional atomisers
Edit
687ECC1 Pump 2YESACC25 ECC1 additional atomisers
Edit
688ECC1 Pump 3YESACC25 ECC1 additional atomisers
Edit
689ECC1 Pump 4YESACC25 ECC1 additional atomisers
Edit
690ECC1 Pump 5YESACC25 ECC1 additional atomisers
Edit
691ECC1 Pump 6YESACC25 ECC1 additional atomisers
Edit
692ECC1 Pump 7YESACC25 ECC1 additional atomisers
Edit
74Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
75Salt Spray / Water Fog pump 1-2 motor or drive interconnectNO
Edit
76Pump 1 pulseNO
Edit
77Pump 2 pulseNO
Edit
78ATCU PLC input I7 - function not namedYESACC29 Refrigeration & humidity control
Edit
79ATCU heater contactor C4 auxiliary feedbackYESACC29 Refrigeration & humidity control
Edit
80 V DC common | 0 V return for optional output cards | Supply to PT100 / analogue cards including ACC34 option | Shared supply/return used by page 15 optional accessories | Shared supply/return to ACC42 / ACC46 / ACC29 accessories | Shared supply/return to ACC92 / ACC31 / ACC66 / ACC59 accessories | Shared power/supply conductor used by ACC30 / ACC102 circuits | Shared supply/return for page 19 optional accessories | Shared supply/return for ACC36 remote transmission and optional remote controlsYES — SHAREDOptional output cards, ACC34 optional PT100, ACC20 / ACC90 / additional pump options, ACC42 / ACC46 / ACC29, ACC92 / ACC31 / ACC66 / ACC59, ACC30 / ACC102, ACC39 / ACC47 / ACC05 / user outputs, ACC36 / Remote controls / Two-button canopyDefined by the wire-identification table on page 1. ACC34 sensor leads are colour/terminal identified rather than assigned separate numeric wire IDs.
Edit
80Blower 1 tachoNO
Edit
81Blower 2 tachoNO
Edit
83ATCU stage 1 HP/LP signal contactYESACC29 Refrigeration & humidity control
Edit
84ATCU stage 1 HP signalYESACC29 Refrigeration & humidity control
Edit
85Base drain valve | Base drainNO
Edit
86ATCU PLC input I15 - function not namedYESACC29 Refrigeration & humidity control
Edit
87Phase feed after MCB30 to optional ATCU power pagesNO
Edit
870ACC29 ATCU phase after MCB21YESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
88Phase feed after MCB30 to optional ATCU power pagesNO
Edit
880ACC29 ATCU phase after MCB21YESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
887Phase feed from X1 to MCB30 / MCB1NO
Edit
888Phase feed from X1 to MCB30 / MCB2NO
Edit
8LACC29 ATCU 0 V DCYESACC29 Refrigeration & humidity controlPages 22 and 24 are titled ACC29 POWER MANAGEMENT (-20 / -40).
Edit
91Low air pressure | Low-air inputNO
Edit
96Air saturator heater inhibit | Air saturator inhibit inputNO
Edit
97-1Blower E6 circuit conductorNO
Edit
97-2Blower E7 circuit conductorNO
Edit
98Blower over-temperature thermostat O/T3 circuitNO
Edit
ESupply earth / protective earthNODefined by the wire-identification table on page 1.
Edit
L1Mains supply phase L1NODefined by the wire-identification table on page 1.
Edit
L2Mains supply phase L2NODefined by the wire-identification table on page 1.
Edit
L3Mains supply phase L3NODefined by the wire-identification table on page 1.
Edit
NMains neutralNODefined by the wire-identification table on page 1.
Edit
N1Neutral before RCD / X1NO
Edit
N2Neutral after RCD / X1 distributionNO
Edit
Add wire manually