Salt Spray Standard
Ascott 120 - 1300
Details
- Status
- Active
- Description
- —
- Parent
- —
Images
No images uploaded.
Bill of materials
Total £0.00| Part | Description | Reference | Qty | Unit | Total | |
|---|---|---|---|---|---|---|
| No BOM lines. | ||||||
Wire numbers
46 wires| Wire | Name / definition | Optional extra | Notes | From | To | |
|---|---|---|---|---|---|---|
| 1 | Cabinet mains live distribution feed to heater circuits | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | |||
| 10 | Over-temperature stat input (O/T chain) | NO | O/T 1 and O/T 2 are wired in series on page 4. | |||
| 1004 | Air saturator heater mains feed between MCB8 and relay K1 | NO | — | |||
| 11 | Series link between O/T 1 and O/T 2 thermostats | NO | — | |||
| 123 | ACC20 full switch input | YESACC20 — Waste Water Trough & Pump System | — | |||
| 14 | Moist air solenoid Y4 | NO | — | |||
| 144 | Internal illumination relay switched-contact bus | YESInternal Illumination (OPTION) | — | |||
| 147 | Salt tank low water alarm input | YES — MODEL/OPTIONSalt Tank Low Water Alarm option; standard on E/F/G | Drawing notes this option is fitted as standard to models E, F and G. | |||
| 15 | Cabinet mains live conductor in the Q1 / RC1 power-management path | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | |||
| 16 | Cabinet mains live conductor from RC1 toward ELEC516.1 | NO | Shown in the non-integral mains-filter arrangement. | |||
| 18 | Emergency stop input | NO | — | |||
| 19 | Canopy open switch input | NO | Page 4 shows the associated pneumatic sensor switch circuit. | |||
| 190 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-8 of this issue. | |||
| 2 | Cabinet mains neutral / common return | YES — SHAREDChart Recorder / accessory circuits — shared mains return | Also feeds optional chart-recorder/accessory circuits. | |||
| 20 | Air saturator auto-fill solenoid Y1 | NO | — | |||
| 200 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-8 of this issue. | |||
| 21 | Air saturator FULL optical sensor | NO | — | |||
| 22 | Air saturator LOW optical sensor | NO | — | |||
| 23 | Vent solenoid Y2 | NO | — | |||
| 236 | Emergency-stop / canopy solenoid interlock conductor | NO | One of the paired interlock conductors shown between S4 and the canopy-solenoid circuit. | |||
| 237 | Emergency-stop / canopy solenoid interlock conductor | NO | One of the paired interlock conductors shown between S4 and the canopy-solenoid circuit. | |||
| 24 | +24 V DC control rail | YES — SHAREDMultiple optional accessories — shared DC control rail | — | |||
| 25 | Open canopy command / solenoid Y10 | NO | Canopy interlock wiring also passes through the emergency-stop circuit. | |||
| 26 | Dry air solenoid Y3 | NO | — | |||
| 27 | Close canopy command / solenoid Y11 | NO | Canopy interlock wiring also passes through the emergency-stop circuit. | |||
| 28 | Canopy closed proximity switch input | NO | — | |||
| 31 | Pump motor black lead (M1 / M6 via PERC010) | YES — SHAREDPump Motor 2 / second pump shares this motor-lead identifier | Used on the standard pump and the optional/model-specific second pump. | |||
| 34 | Buzzer | NO | — | |||
| 35 | Air saturator heater E2 load conductor | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | |||
| 36 | Air saturator heater control | NO | — | |||
| 37 | Chamber / cabinet heater relay K2 control | NO | PLC page names the output 'Chamber Heater'. | |||
| 39 | Cabinet heater load conductor | NO | Feeds E4/A, E4/B and E4/C as applicable by model. | |||
| 4 | AC live accessory / chart-recorder feed | YES — SHAREDInternal Illumination; Chart Recorder options | Used by the internal-illumination and chart-recorder branches. | |||
| 400 | Chart recorder / independent PT100 option signal link via 10 Ω resistor | YESChart Recorder / Independent PT100 option | — | |||
| 44 | Internal illumination switched lamp feed | YESInternal Illumination (OPTION) | — | |||
| 441 | ACC92 option output to Y50 / V3 | YESACC92 option | The drawing identifies the output as ACC92 but does not further name its function. | |||
| 45 | Internal illumination relay command | YESInternal Illumination (OPTION) | — | |||
| 5 | Pump motor red lead (M1 / M6 via PERC010) | YES — SHAREDPump Motor 2 / second pump shares this motor-lead identifier | Used on the standard pump and the optional/model-specific second pump. | |||
| 60 | High water warning lamp | YESHigh Water Lamp (OPTION) | — | |||
| 7 | Purge solenoid Y5 | NO | — | |||
| 76 | Pump motor 1 command | NO | — | |||
| 77 | Pump motor 2 command | YESPump Motor 2 / second pump (Model D only) | Page 6 explicitly labels Pump Motor 2 as optional; page 3 shows Model D only. | |||
| 8 | 0 V DC control rail | YES — SHAREDMultiple optional accessories — shared DC control rail | — | |||
| 87 | Protected mains live interconnect in the mains filter / RC1 path | NO | Listed on page 1 as a cabinet-mains (>3 A) wire identifier. | |||
| 88 | Cabinet mains (>3 A) identifier listed in the wire standard | NO | Not otherwise observed on pages 2-8 of this issue. | |||
| 96 | Air saturator inhibit input | NO | — |