CP Chamber Parts

machine

Salt Spray Standard

Ascott 120 - 1300

Edit

Details

Status
Active
Description
Parent

Images

Bill of materials

Total £0.00
PartDescriptionReferenceQtyUnitTotal
No BOM lines.

Wire numbers

46 wires
WireName / definitionOptional extraNotesFromTo
1Cabinet mains live distribution feed to heater circuitsNOListed on page 1 as a cabinet-mains (>3 A) wire identifier.
Edit
10Over-temperature stat input (O/T chain)NOO/T 1 and O/T 2 are wired in series on page 4.
Edit
1004Air saturator heater mains feed between MCB8 and relay K1NO
Edit
11Series link between O/T 1 and O/T 2 thermostatsNO
Edit
123ACC20 full switch inputYESACC20 — Waste Water Trough & Pump System
Edit
14Moist air solenoid Y4NO
Edit
144Internal illumination relay switched-contact busYESInternal Illumination (OPTION)
Edit
147Salt tank low water alarm inputYES — MODEL/OPTIONSalt Tank Low Water Alarm option; standard on E/F/GDrawing notes this option is fitted as standard to models E, F and G.
Edit
15Cabinet mains live conductor in the Q1 / RC1 power-management pathNOListed on page 1 as a cabinet-mains (>3 A) wire identifier.
Edit
16Cabinet mains live conductor from RC1 toward ELEC516.1NOShown in the non-integral mains-filter arrangement.
Edit
18Emergency stop inputNO
Edit
19Canopy open switch inputNOPage 4 shows the associated pneumatic sensor switch circuit.
Edit
190Cabinet mains (>3 A) identifier listed in the wire standardNONot otherwise observed on pages 2-8 of this issue.
Edit
2Cabinet mains neutral / common returnYES — SHAREDChart Recorder / accessory circuits — shared mains returnAlso feeds optional chart-recorder/accessory circuits.
Edit
20Air saturator auto-fill solenoid Y1NO
Edit
200Cabinet mains (>3 A) identifier listed in the wire standardNONot otherwise observed on pages 2-8 of this issue.
Edit
21Air saturator FULL optical sensorNO
Edit
22Air saturator LOW optical sensorNO
Edit
23Vent solenoid Y2NO
Edit
236Emergency-stop / canopy solenoid interlock conductorNOOne of the paired interlock conductors shown between S4 and the canopy-solenoid circuit.
Edit
237Emergency-stop / canopy solenoid interlock conductorNOOne of the paired interlock conductors shown between S4 and the canopy-solenoid circuit.
Edit
24+24 V DC control railYES — SHAREDMultiple optional accessories — shared DC control rail
Edit
25Open canopy command / solenoid Y10NOCanopy interlock wiring also passes through the emergency-stop circuit.
Edit
26Dry air solenoid Y3NO
Edit
27Close canopy command / solenoid Y11NOCanopy interlock wiring also passes through the emergency-stop circuit.
Edit
28Canopy closed proximity switch inputNO
Edit
31Pump motor black lead (M1 / M6 via PERC010)YES — SHAREDPump Motor 2 / second pump shares this motor-lead identifierUsed on the standard pump and the optional/model-specific second pump.
Edit
34BuzzerNO
Edit
35Air saturator heater E2 load conductorNOListed on page 1 as a cabinet-mains (>3 A) wire identifier.
Edit
36Air saturator heater controlNO
Edit
37Chamber / cabinet heater relay K2 controlNOPLC page names the output 'Chamber Heater'.
Edit
39Cabinet heater load conductorNOFeeds E4/A, E4/B and E4/C as applicable by model.
Edit
4AC live accessory / chart-recorder feedYES — SHAREDInternal Illumination; Chart Recorder optionsUsed by the internal-illumination and chart-recorder branches.
Edit
400Chart recorder / independent PT100 option signal link via 10 Ω resistorYESChart Recorder / Independent PT100 option
Edit
44Internal illumination switched lamp feedYESInternal Illumination (OPTION)
Edit
441ACC92 option output to Y50 / V3YESACC92 optionThe drawing identifies the output as ACC92 but does not further name its function.
Edit
45Internal illumination relay commandYESInternal Illumination (OPTION)
Edit
5Pump motor red lead (M1 / M6 via PERC010)YES — SHAREDPump Motor 2 / second pump shares this motor-lead identifierUsed on the standard pump and the optional/model-specific second pump.
Edit
60High water warning lampYESHigh Water Lamp (OPTION)
Edit
7Purge solenoid Y5NO
Edit
76Pump motor 1 commandNO
Edit
77Pump motor 2 commandYESPump Motor 2 / second pump (Model D only)Page 6 explicitly labels Pump Motor 2 as optional; page 3 shows Model D only.
Edit
80 V DC control railYES — SHAREDMultiple optional accessories — shared DC control rail
Edit
87Protected mains live interconnect in the mains filter / RC1 pathNOListed on page 1 as a cabinet-mains (>3 A) wire identifier.
Edit
88Cabinet mains (>3 A) identifier listed in the wire standardNONot otherwise observed on pages 2-8 of this issue.
Edit
96Air saturator inhibit inputNO
Edit
Add wire manually