Machine wiring

Wire numbers by machine

Select a machine or search across the complete wire register.

Import Excel
Clear

Wire register

87 results
MachineWire numberName / definitionOptional extraNotesFromTo
ATCUATCU -40 200 - 240VAC 3 PH0AC neutral / control neutralYES — SHAREDPsychometric Unit OptionShared standard neutral. It also returns the GP35 pump circuit associated with the psychometric option.Edit
ATCUATCU -40 200 - 240VAC 3 PH13-phase distribution conductorNOThe '1' shown at the Psychometric Unit connector on page 3 is a connector pin, not this wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH10Stage 1 compressor phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH1003-phase power conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH1013-phase power conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH1023-phase power conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH11Stage 2 compressor phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH110Transformer secondary phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH111Transformer secondary phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH112Transformer secondary phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH114Heater supply phaseNOEdit
ATCUATCU -40 200 - 240VAC 3 PH115Heater supply phaseNOEdit
ATCUATCU -40 200 - 240VAC 3 PH116Heater supply phaseNOEdit
ATCUATCU -40 200 - 240VAC 3 PH12Stage 2 compressor phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH122Condenser fan branch feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH123Condenser fan switched feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH124De-superheater fan branch feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH125De-superheater fan switched feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH126Crankcase-heater branch feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH127Crankcase heater stage 1 switched feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH128Crankcase heater stage 2 switched feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH13Stage 2 compressor phase conductorNOThe '13' shown beside B1 on page 3 is a connector pin, not this power wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH14Heater phase feed after contactor C4NOThe '14' shown beside B1 on page 3 is a connector pin, not this power wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH15Heater phase feed after contactor C4NOThe '15' shown beside B1 on page 3 is a connector pin, not this power wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH150Stage 1 COOL solenoid feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH151Stage 1 BYPASS solenoid feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH152Stage 2 COOL solenoid feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH153Stage 2 BYPASS solenoid feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH154DEHUMID solenoid feedNOEdit
ATCUATCU -40 200 - 240VAC 3 PH16Heater phase feed after contactor C4NOThe '16' shown beside B2 on page 3 is a connector pin, not this power wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH164Plant healthy outputNOEdit
ATCUATCU -40 200 - 240VAC 3 PH17Heater switched outputNOEdit
ATCUATCU -40 200 - 240VAC 3 PH18Heater switched outputNOEdit
ATCUATCU -40 200 - 240VAC 3 PH19Heater switched outputNOEdit
ATCUATCU -40 200 - 240VAC 3 PH23-phase distribution conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH210HEAT commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH24+24 V DC control supplyNOPage 1 standard: pink, 0.5 mm². The explicitly marked Psychometric Unit option does not show a direct 24 V wire connection.Edit
ATCUATCU -40 200 - 240VAC 3 PH248GP35 pump switched AC feedYESPsychometric Unit OptionRevision H states the psychometric fill/drain valves were replaced by a pump; this is the GP35 pump circuit.Edit
ATCUATCU -40 200 - 240VAC 3 PH265RUN commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH286HUMIDIFY commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH289Psychometric option control signalYESPsychometric Unit OptionExplicitly inside the area labelled 'PSYCHOMETRIC UNIT OPTION' and routed to SSR9.Edit
ATCUATCU -40 200 - 240VAC 3 PH33-phase distribution conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH4AC live / control supply feedYES — SHAREDPsychometric Unit OptionShared standard AC feed. SSR9 uses it to switch the optional GP35 psychometric pump.Edit
ATCUATCU -40 200 - 240VAC 3 PH43Air circulation fan contactor commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH44Stage 1 compressor contactor commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH45Stage 2 compressor contactor commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH46Heater contactor command before over-temperature interlockNOEdit
ATCUATCU -40 200 - 240VAC 3 PH5Air circulation fan phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH50Stage 1 cooling-solenoid relay commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH51Stage 1 bypass-solenoid relay commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH52Stage 2 cooling-solenoid relay commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH53Stage 2 bypass-solenoid relay commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH54Dehumidification solenoid relay commandNOFunction follows the Q8-Q12 relay/solenoid sequence shown on page 3.Edit
ATCUATCU -40 200 - 240VAC 3 PH55PLC output Q13NOFunction not defined by the source drawing.Edit
ATCUATCU -40 200 - 240VAC 3 PH560DEHUMID command / control signalNODehumidifier is shown as part of the ATCU circuit and is not explicitly labelled optional.Edit
ATCUATCU -40 200 - 240VAC 3 PH57Heater contactor command after OT2NOEdit
ATCUATCU -40 200 - 240VAC 3 PH6Air circulation fan phase conductorNOEdit
ATCUATCU -40 200 - 240VAC 3 PH68COOL commandNOEdit
ATCUATCU -40 200 - 240VAC 3 PH7Air circulation fan phase conductorNOThe '7' shown at the Psychometric Unit connector on page 3 is a connector pin, not this wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH74Air temperature limit inputNOEdit
ATCUATCU -40 200 - 240VAC 3 PH75PLC input I4NOFunction not defined by the source drawing.Edit
ATCUATCU -40 200 - 240VAC 3 PH76PLC input I5NOFunction not defined by the source drawing.Edit
ATCUATCU -40 200 - 240VAC 3 PH77PLC input I6NOFunction not defined by the source drawing.Edit
ATCUATCU -40 200 - 240VAC 3 PH78PLC input I7NOFunction not defined by the source drawing.Edit
ATCUATCU -40 200 - 240VAC 3 PH79Heater contactor feedbackNOEdit
ATCUATCU -40 200 - 240VAC 3 PH8Stage 1 compressor phase conductor | 0 V DC commonYES — SHAREDPsychometric Unit OptionContext-specific use on the power circuit; the drawing also uses wire 8 as the 0 V DC identifier. Page 1 standard: violet, 0.5 mm². Shared 0 V rail; SSR9 for the psychometric option returns on wire 8.Edit
ATCUATCU -40 200 - 240VAC 3 PH80Recirculation fan overload feedbackNOEdit
ATCUATCU -40 200 - 240VAC 3 PH81Stage 1 compressor overload feedbackNOEdit
ATCUATCU -40 200 - 240VAC 3 PH82Stage 2 compressor overload feedbackNOEdit
ATCUATCU -40 200 - 240VAC 3 PH83Stage 1 pressure-switch feedbackNOThe drawing shows two Stage 1 HP/LP1 feedback conductors, 83 and 84.Edit
ATCUATCU -40 200 - 240VAC 3 PH84Stage 1 pressure-switch feedbackNOThe drawing shows two Stage 1 HP/LP1 feedback conductors, 83 and 84.Edit
ATCUATCU -40 200 - 240VAC 3 PH85Stage 2 pressure-switch feedbackNOThe drawing shows two Stage 2 HP/LP1 feedback conductors, 85 and 86.Edit
ATCUATCU -40 200 - 240VAC 3 PH86Stage 2 pressure-switch feedbackNOThe drawing shows two Stage 2 HP/LP1 feedback conductors, 85 and 86.Edit
ATCUATCU -40 200 - 240VAC 3 PH87Stage 2 HP1 feedbackNOEdit
ATCUATCU -40 200 - 240VAC 3 PH9Stage 1 compressor phase conductorNOThe '9' shown at the Psychometric Unit connector on page 3 is a connector pin, not this wire.Edit
ATCUATCU -40 200 - 240VAC 3 PH92Heater SSR controlNOEdit
ATCUATCU -40 200 - 240VAC 3 PH93Y3 solenoid commandNODrawing does not give a separate functional label for Y3.Edit
ATCUATCU -40 200 - 240VAC 3 PHESupply earth / protective earthNOPage 1 wire-identification standard.Edit
ATCUATCU -40 200 - 240VAC 3 PHL1Mains supply phase L1NOPage 1 standard: black, 4 mm².Edit
ATCUATCU -40 200 - 240VAC 3 PHL11Phase conductor after main RCDNOEdit
ATCUATCU -40 200 - 240VAC 3 PHL2Mains supply phase L2NOPage 1 standard: black, 4 mm².Edit
ATCUATCU -40 200 - 240VAC 3 PHL21Phase conductor after main RCDNOEdit
ATCUATCU -40 200 - 240VAC 3 PHL3Mains supply phase L3NOPage 1 standard: black, 4 mm².Edit
ATCUATCU -40 200 - 240VAC 3 PHL31Phase conductor after main RCDNOEdit
ATCUATCU -40 200 - 240VAC 3 PHRIncoming supply phase identifierNOSupply label rather than a numbered control wire.Edit
ATCUATCU -40 200 - 240VAC 3 PHSIncoming supply phase identifierNOSupply label rather than a numbered control wire.Edit
ATCUATCU -40 200 - 240VAC 3 PHTIncoming supply phase identifierNOSupply label rather than a numbered control wire.Edit