MachineWire numberName / definitionOptional extraNotesFromTo
Salt Spray Premium120 - 13001Cabinet mains live distribution feed from the mains filter / RCBO path to K30 L1 and page 3 circuitsNOListed on page 1 as a cabinet-mains (>3 A) wire identifier.Edit
Salt Spray Premium120 - 130010O/T 1 over-temperature inputNOPage 4 shows wire 10 from the O/T chain to the PLC.Edit
Salt Spray Premium120 - 13001004Air-saturator heater branch between K1 and MCB4NOEdit
Salt Spray Premium120 - 1300101Switched mains live bus from K30 feeding heater relay contactsNOFeeds K10 and K2 directly and K1 through MCB4.Edit
Salt Spray Premium120 - 1300107Cabinet heater E4/B model-specific load conductorNOShown for models B, C, D, F, G, J, K and L.Edit
Salt Spray Premium120 - 1300108Cabinet heater E4/C model-specific load conductorNOShown for models B, C, D, J, K and L.Edit
Salt Spray Premium120 - 130011O/T 2 input and over-temperature safety link to K30NOWire 11 also connects the O/T chain to relay K30 A1 on page 3.Edit
Salt Spray Premium120 - 1300123ACC20 full-switch inputYESACC20 — optionEdit
Salt Spray Premium120 - 1300125ACC92 scrubber-flow inputYESACC92 — Scrubber Flow MeterEdit
Salt Spray Premium120 - 1300132Pump M2 red motor lead between F2V2 and PERC010NOEdit
Salt Spray Premium120 - 130014Moist air solenoid Y4 commandNOEdit
Salt Spray Premium120 - 1300144Internal-illumination protected live feed from MCB3 to K17 contactsYESInternal Illumination (OPTION)Edit
Salt Spray Premium120 - 1300147Salt-tank low-water alarm inputNO — MODEL DEPENDENTPage 7 states NOT FITTED TO A AND I MODELS; it is not explicitly labelled as an option in this issue.Edit
Salt Spray Premium120 - 130015Switched mains live conductor between Q1 and the RCBONOUsed in both mains-filter arrangements.Edit
Salt Spray Premium120 - 130016Protected neutral interconnect from the RCBO to ELEC516.1NOShown in the non-integral mains-filter arrangement.Edit
Salt Spray Premium120 - 1300163High-water inputNO — MODEL DEPENDENTPage 4 shows the high-water optical sensor circuit fitted to models A and I only.Edit
Salt Spray Premium120 - 1300173Water LOW inputNOEdit
Salt Spray Premium120 - 130018Emergency-stop status inputNOEdit
Salt Spray Premium120 - 130019Canopy opened switch inputNOPage 4 shows the pneumatic sensor-switch circuit.Edit
Salt Spray Premium120 - 1300190Cabinet mains (>3 A) identifier listed in the wire standardNONot otherwise observed on pages 2-7 of this issue.Edit
Salt Spray Premium120 - 13002Cabinet mains neutral / common return to heater and accessory circuitsYES — SHAREDInternal Illumination option — shared mains returnAlso returns the optional internal-illumination lamp circuit.Edit
Salt Spray Premium120 - 130020Air-saturator auto-fill solenoid Y1 commandNOEdit
Salt Spray Premium120 - 1300200Cabinet mains (>3 A) identifier listed in the wire standardNONot otherwise observed on pages 2-7 of this issue.Edit
Salt Spray Premium120 - 13002000Immersion-heater neutral-side conductor shown at E7/ANOPage 1 revision F references neutral wire 2000; later revision G says neutral is no longer through the contactor. Page 3 still labels E7/A with 2000.Edit
Salt Spray Premium120 - 130021Air-saturator FULL optical sensor inputNOEdit
Salt Spray Premium120 - 130022Air-saturator LOW optical sensor inputNOEdit
Salt Spray Premium120 - 1300236Canopy-open solenoid conductor after the emergency-stop contactsNOConnects S4 to the canopy OPEN solenoid Y10.Edit
Salt Spray Premium120 - 1300237Canopy-close solenoid conductor after the emergency-stop contactsNOConnects S4 to the canopy CLOSE solenoid Y11.Edit
Salt Spray Premium120 - 130024+24 V DC control railYES — SHAREDHUMA030 RH1; ACC20; ACC92; ACC102; ACC05 and optional I/O — shared +24 V railEdit
Salt Spray Premium120 - 130025Open-canopy command on PLC / emergency-stop sideNOPasses through S4; the solenoid-side conductor is wire 236.Edit
Salt Spray Premium120 - 130026Dry air solenoid Y3 commandNOEdit
Salt Spray Premium120 - 130027Close-canopy command on PLC / emergency-stop sideNOPasses through S4; the solenoid-side conductor is wire 237.Edit
Salt Spray Premium120 - 130028Canopy closed proximity-switch inputNOEdit
Salt Spray Premium120 - 130031Pump M1 black motor lead between F2V1 and PERC010NOEdit
Salt Spray Premium120 - 130032Pump M2 black motor lead between F2V2 and PERC010NOEdit
Salt Spray Premium120 - 130034Buzzer commandNOEdit
Salt Spray Premium120 - 130035Air-saturator heater E2 load conductor to relay K1NOListed on page 1 as a cabinet-mains (>3 A) wire identifier.Edit
Salt Spray Premium120 - 130036Air-saturator heater relay K1 controlNOEdit
Salt Spray Premium120 - 130037Chamber / cabinet heater relay K2 controlNOPLC page labels this output CHAMBER HEATER.Edit
Salt Spray Premium120 - 130038Immersion-heater relay K10 controlNOEdit
Salt Spray Premium120 - 130039Cabinet heater E4/A load conductor to relay K2NOOther model-specific cabinet-heater branches use wires 107 and 108.Edit
Salt Spray Premium120 - 13004Protected AC live distribution from MCB2 to the 24 V PSU and accessory branchYES — SHAREDInternal Illumination option — shared protected live feedFeeds PLCC303 L and the optional internal-illumination MCB3 branch.Edit
Salt Spray Premium120 - 130044Internal-illumination switched lamp / relay-contact conductorYESInternal Illumination (OPTION)Shown only inside the INTERNAL ILLUMINATION (OPTION) box.Edit
Salt Spray Premium120 - 130045Internal-illumination relay K17 commandYESInternal Illumination (OPTION)Edit
Salt Spray Premium120 - 1300470Guardian Angel fatal-error warningYESACC05 — Guardian Angel (OPTION)Edit
Salt Spray Premium120 - 1300471Guardian Angel non-fatal error warningYESACC05 — Guardian Angel (OPTION)Edit
Salt Spray Premium120 - 1300472Guardian Angel system-healthy outputYESACC05 — Guardian Angel (OPTION)Edit
Salt Spray Premium120 - 13005Pump M1 red motor lead between F2V1 and PERC010NOEdit
Salt Spray Premium120 - 130054Immersion heater E7/A load conductor to relay K10NOListed on page 1 as a cabinet-mains (>3 A) wire identifier; used on models B, C, J and K.Edit
Salt Spray Premium120 - 130058Air-curtain solenoid Y33 commandNOEdit
Salt Spray Premium120 - 130059Base-fill solenoid group commandNOPage 3 shows wire 59 driving the base-fill valve group.Edit
Salt Spray Premium120 - 13006HUMA030 RH1 humidity-probe analogue signal (white lead)YESHUMA030 RH1 humidity probe (OPTIONAL)HUMA030 RH1 is explicitly shown inside an OPTIONAL box.Edit
Salt Spray Premium120 - 130060Optional-accessory output; page 6 says AIR SATURATOR MANUAL FILL, page 7 shows HIGH WATER LEVEL lampYES — OPTIONAL I/OOptional accessories card / High Water Level circuitThe drawing gives two different function labels for wire 60; both are retained here rather than reconciled.Edit
Salt Spray Premium120 - 130063O/T 8 over-temperature inputNOEdit
Salt Spray Premium120 - 130064O/T 7 over-temperature inputNOEdit
Salt Spray Premium120 - 130065O/T 12 over-temperature inputNOPLC page labels wire 65 O/T 12; page 4 shows it as a branch from the additional O/T chain.Edit
Salt Spray Premium120 - 13007Purge solenoid Y5 commandNOEdit
Salt Spray Premium120 - 130076Pump 1 pulse / speed commandNOEdit
Salt Spray Premium120 - 130077Pump 2 pulse / speed commandNOEdit
Salt Spray Premium120 - 130080 V DC control railYES — SHAREDHUMA030 RH1; ACC20; ACC92; ACC102; ACC46; ACC05; Internal Illumination — shared 0 V railEdit
Salt Spray Premium120 - 130083SO2 fill solenoid Y26 commandYESACC46 — SO2 FillEdit
Salt Spray Premium120 - 130087Mains live interconnect in the filter / RCBO pathNOIts position changes with the integral vs non-integral filter arrangement.Edit
Salt Spray Premium120 - 130088Filtered neutral interconnect from ELEC514 toward Q1NOShown in the mains-filter-integral-to-connector arrangement.Edit
Salt Spray Premium120 - 13009PNEC069 S5 air-pressure sensor analogue signal (black lead)NOBrown/blue are supply/return; wire 9 is the signal into PLCC017.Edit
Salt Spray Premium120 - 130096Air-saturator heater-inhibit optical sensor inputNOEdit