Live progress
Connecting…Checking current work…
—
—
—
—
Available when reported by Ollama
—
Updates every three seconds. Saved-page progress advances after a whole page commits. Character counts show output received for the current model request; they are not a completion percentage. During input processing Ollama may emit no output. No estimated finish time is guessed.
all · unkown
PILZ / P02
Ask about this document Delete document
29 of 29 pages analysed. 30 extracted records across all pages.
Completed page timings
PDF page 1 · direct-text · No AI: PDF text
PDF page 2 · direct-text · No AI: PDF text
PDF page 3 · direct-text · No AI: PDF text
PDF page 4 · direct-text · No AI: PDF text
PDF page 5 · direct-text · No AI: PDF text
PDF page 6 · direct-text · No AI: PDF text
PDF page 7 · direct-text · No AI: PDF text
PDF page 8 · direct-text · No AI: PDF text
PDF page 9 · direct-text · No AI: PDF text
PDF page 10 · direct-text · No AI: PDF text
PDF page 11 · direct-text · No AI: PDF text
PDF page 12 · direct-text · No AI: PDF text
PDF page 13 · direct-text · No AI: PDF text
PDF page 14 · direct-text · No AI: PDF text
PDF page 15 · direct-text · No AI: PDF text
PDF page 16 · direct-text · No AI: PDF text
PDF page 17 · direct-text · No AI: PDF text
PDF page 18 · direct-text · No AI: PDF text
PDF page 19 · direct-text · No AI: PDF text
PDF page 20 · direct-text · No AI: PDF text
PDF page 21 · direct-text · No AI: PDF text
PDF page 22 · direct-text · No AI: PDF text
PDF page 23 · direct-text · No AI: PDF text
PDF page 24 · direct-text · No AI: PDF text
PDF page 25 · direct-text · No AI: PDF text
PDF page 26 · direct-text · No AI: PDF text
PDF page 27 · direct-text · No AI: PDF text
PDF page 28 · direct-text · No AI: PDF text
PDF page 29 · direct-text · No AI: PDF text
Timings include page extraction, rendering where needed, and model requests. Earlier pages may have no timing.
PDF text index
This text was copied from the PDF without AI interpretation. Indexed does not mean reviewed or approved. Check reading order against the PDF. Pages listed above may need OCR or may be blank.
Search source text / askCompare each record with the PDF. Model certainty is an unverified judgement. Page numbers below are PDF page positions, not printed sheet numbers. Approval adds knowledge-base evidence; it does not overwrite the existing machine wire register.
0 1 2 3 4 5 6 7 8 9 A B F A B C D E F Iputs/Outputs D3 Project: Date: Function: Drawing no.: Location: Init.: Rev.: 9 Sheet: 10 Total sheets: Next sheet: 22 11/04/2024 Associated British Ports ABP ABP Southampton Ocean Gate Atlantic Way Southampton SO14 3QN 19322SQ ABP Southampton Sliding Door & Gate System 24v 1T1 8.9 24v 1T1 11.0 0v1T1 8.9 0v1T1 11.0 64 SR4 Inverter i19 7.8 S50 Controls On/Off 3 4 42 42 42 Controls On/Off 8.8 84 84 84 9 11 3 10 8 4 5 6 7 Out Ch.1 Out Ch.2 SE1 ELMON Relay 32-242 Safety Edge Controller 85 84 84 84 84 95 95 95 X1 61 X1 62 X1 63 X1 64 124 122 123 123 123 66 Radio Unit Safety - i21 11.3 65 65 65 65 84 84 84 84 84 P5 LHS Over Travel 85 P6 RHS Over Travel 85 X1 22 100 X1 26 101 X1 70 X1 69 X1 42 X1 41 42 Sensor Box 2nd Sensor 12.0 0v1t1 Sensors 12.0 24v 1t1 Sensors 12.1 X1 16 67 X1 29 85 X1 30 84 96 7 84 SPBB Connected Common 108 Input 1 S 11.1 109 Input 1 R 11.1 SK20 A1 A2 SK21 A1 A2 65 X1 47 99 X1 51 98 85 131 85 130 84 84 84 84 84 Door B2 Sens SR8/i17 23.8 143 Door C2 Sens SR10/i24 24.8 145 SK29 A1 A2 85 159 SK30 A1 A2 85 160 NO NC 3.2 11 7 3 3.3 12 8 4 10 6 2 9 5 1 3.4 11 7 3 3.5 12 8 4 10 6 2 9 5 1 20.4 11 7 3 4.7 12 8 4 10 6 2 9 5 1 11 7 3 20.5 12 8 4 7.3 10 6 2 9 5 1
→ · · PDF text; not AI interpreted