Live progress
Connecting…Checking current work…
—
—
—
—
Available when reported by Ollama
—
Updates every three seconds. Saved-page progress advances after a whole page commits. Character counts show output received for the current model request; they are not a completion percentage. During input processing Ollama may emit no output. No estimated finish time is guessed.
all · unkown
PILZ / P02
Ask about this document Delete document
29 of 29 pages analysed. 30 extracted records across all pages.
Completed page timings
PDF page 1 · direct-text · No AI: PDF text
PDF page 2 · direct-text · No AI: PDF text
PDF page 3 · direct-text · No AI: PDF text
PDF page 4 · direct-text · No AI: PDF text
PDF page 5 · direct-text · No AI: PDF text
PDF page 6 · direct-text · No AI: PDF text
PDF page 7 · direct-text · No AI: PDF text
PDF page 8 · direct-text · No AI: PDF text
PDF page 9 · direct-text · No AI: PDF text
PDF page 10 · direct-text · No AI: PDF text
PDF page 11 · direct-text · No AI: PDF text
PDF page 12 · direct-text · No AI: PDF text
PDF page 13 · direct-text · No AI: PDF text
PDF page 14 · direct-text · No AI: PDF text
PDF page 15 · direct-text · No AI: PDF text
PDF page 16 · direct-text · No AI: PDF text
PDF page 17 · direct-text · No AI: PDF text
PDF page 18 · direct-text · No AI: PDF text
PDF page 19 · direct-text · No AI: PDF text
PDF page 20 · direct-text · No AI: PDF text
PDF page 21 · direct-text · No AI: PDF text
PDF page 22 · direct-text · No AI: PDF text
PDF page 23 · direct-text · No AI: PDF text
PDF page 24 · direct-text · No AI: PDF text
PDF page 25 · direct-text · No AI: PDF text
PDF page 26 · direct-text · No AI: PDF text
PDF page 27 · direct-text · No AI: PDF text
PDF page 28 · direct-text · No AI: PDF text
PDF page 29 · direct-text · No AI: PDF text
Timings include page extraction, rendering where needed, and model requests. Earlier pages may have no timing.
PDF text index
This text was copied from the PDF without AI interpretation. Indexed does not mean reviewed or approved. Check reading order against the PDF. Pages listed above may need OCR or may be blank.
Search source text / askCompare each record with the PDF. Model certainty is an unverified judgement. Page numbers below are PDF page positions, not printed sheet numbers. Approval adds knowledge-base evidence; it does not overwrite the existing machine wire register.
0 1 2 3 4 5 6 7 8 9 A B C D E F A B C D E F SPBB Transciever Wiring Team 1 Project: Date: Function: Drawing no.: Location: Init.: Rev.: 18 Sheet: 19 Total sheets: Next sheet: 22 07/11/2024 Associated British Ports ABP ABP Southampton Ocean Gate Atlantic Way Southampton SO14 3QN 19322SQ ABP Southampton Sliding Door & Gate System 24vdc SPBB Team 1 24vdc SPBB Team 1 19.0 0vdc SPBB Team 1 0vdc SPBB Team 1 19.0 Input Card Door 1 Input 1S Input 1R Input 2S Input 2R Input 3S Input 3R Input 4S Input 4R 24V- 24V+ Input Card5 Input Card Door 2 Input 1S Input 1R Input 2S Input 2R Input 3S Input 3R Input 4S Input 4R 24V- 24V+ Input Card6 SK18 19.2 9 5 SK19 19.3 11 7 S71 Building Doors Right Travel 3 4 S72 Building Doors Left Travel 3 4 SK18 19.2 11 7 SK19 19.3 12 8 SK18 19.2 12 8 SK19 19.3 10 6 Please note, this page is not part of the EDS wiring details, this is a proposed wiring for Adelte to install within there controls for the Transmission System EDS will supply all Transmission Equipement pre-programmed. Adelte will utilise there own 24vdc power, push buttons, relays, 3 position and 5 position switches All numbering details are for information only 7 Output linked to SPBB to enable key to be relased when Building door is in position Normally open going closed Input 1 S Input 1 R Input 2 S 24V- 24V+ NO COM NC NO COM NC Team 1 Radio Tran1 Input 2 R Output from each building door, these can be linked to SPBB to enable key to be relased when Building door is in position Normally open going closed (Optional) Channel Ra2 Relay Card NO COM NC NO COM NC NO COM NC NO COM NC 24V- 24V+
→ · · PDF text; not AI interpreted